| 2019-06-17 13:10:34 | ADDRESS: 145 BLOOMFIELD DR PERMIT # 19051263 |
| | TYPE: BLD-RES NEW SFR |
| | |
| | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | 1&2 FAMILY PLANS EXAMINER, SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 |
| | 6TH EDITION |
| | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH |
| | EDITION |
| | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION |
| | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1. VALUE HAS BEE ADJUSTED FROM $650,00 TO $716,355 |
| | BASED ON THE ICC BUILDING VALUATION DATA PUBLISHED FEB. |
| | 2019. |
| | 109.3 BUILDING PERMIT VALUATIONS. |
| | |
| | 2. DIGITAL SIGNATURES ARE INVALID. |
| | A. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH |
| | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE |
| | NEXT REVIEW CYCLE REQUIRE REVIEW. |
| | B. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. |
| | |
| | 3. FINISH FLOOR ELEVATION OF 8'1" NAVD 88 - OK. NO |
| | RESPONSE NECESSARY |
| | |
| | 4. NFIP - PROPERTY IS LOCATED IN FLOOD ZONE AE WITH A |
| | BASE FLOOD ELEVATION (BFE) OF 6'0" NAVD88. AMENDMENTS |
| | TO THE CITY OF WEST PALM BEACH, ORDINANCE NO. 4729-17 |
| | REQUIRES 2 FEET OF FREE BOARD. DESIGN FLOOD ELEVATION |
| | (DFE) WILL BE AT 8'0" NAVD88. |
| | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT |
| | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE |
| | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD |
| | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM |
| | BEACH, FL. |
| | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON |
| | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM |
| | BEACH, BY ORDINANCE, ESTABLISHED A TWO FOOT FREEBOARD |
| | ABOVE THE (BFE). |
| | |
| | ELEVATION CERTIFICATES REQUIRED. |
| | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS |
| | REQUIRED AT TIME OF PERMIT APPLICATION. MINIMUM FINISH |
| | FLOOR ELEVATION SHALL BE 8'0" NAVD88. |
| | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS |
| | SITE ARE REQUIRED TO BE AT OR ABOVE 8 FEET NAVD. |
| | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED |
| | FLOOR ELEVATION IS REQUIRED. |
| | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| | THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING |
| | FINAL. |
| | |
| | 5. FLOOD VENTS REQUIRED IN ATTACHED GARAGE. |
| | G1001.4 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. |
| | FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION |
| | SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO |
| | THE FOLLOWING: |
| | |
| | 1. IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY |
| | WAVE ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS |
| | TO ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF |
| | FLOODWATERS. |
| | |
| | 6. PALM BEACH COUNTY IMPACT FEE REQUIRED. |
| | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL |
| | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE |
| | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE |
| | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS |
| | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE |
| | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE |
| | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD |
| | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
| | |
| | 7. SITE DRAINAGE PLAN PAGE C-1 SHOWS A DETAIL FOR A |
| | TYPICAL YARD DRAIN. IDENTIFY THE LOCATION OF EACH DRAIN |
| | AND DRAIN DISCHARGE ON PLAN. |
| | |
| | 8. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXTERIOR |
| | DOORS. |
| | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. |
| | |
| | OPTION |
| | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS |
| | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE |
| | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE |
| | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO |
| | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. |
| | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR |
| | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED |
| | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST |
| | THE DEFERRED SUBMITTALS ON |
| | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING |
| | OFFICIAL. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 9. PROVIDE DESIGN PRESSURES FOR ALL BUILDING OPENINGS. |
| | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN |
| | PRESSURES PURSUANT TO FBC-R301.2. |
| | |
| | 10. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR |
| | THE ICYNENE SPRAY FOAM INSULATION. INDICATE WHICH |
| | SYSTEM WILL BE USED TO ACHIEVE THE R-30 RATING OF THE |
| | CEILING INSULATION. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |