 1ST REVIEW: FBC 2017 6TH EDITION
 1ST REVIEW FBC 2017 EXISTING BUILDING
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CHANGE OCCUPANCY; MIXED USE GROUP B & R2 AS PER
 508.1 FBC
 2. CHANGE ALTERATION LEVEL TO LEVEL 3 ALTERATION AS PER
 505.1 FBC-EB
 3. AN ENGINEERING EVALUATION AND ANALYSIS THAT
 ESTABLISHES THE STRUCTURAL ADEQUACY OF THE ALTERED
 STRUCTURE SHALL BE PREPARED BY A REGISTERED DESIGN
 PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. AS PER
 907.4.1 AND 907.4.2 FBC-EB.
 4. THE STRUCTURAL FRAME AND ROOF CONSTRUCTION
 SUPPORTING IMPOSED LOADS UPON THE ROOF BY ANY ROOFTOP
 STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF TABLE
 601. THE FIRE-RESISTANCE REDUCTION PERMITTED BY TABLE
 601, NOTE A, SHALL NOT APPLY TO ROOFS CONTAINING
 ROOFTOP STRUCTURES. AS PER 1510.9 FBC.
 5. ROOFTOP STRUCTURES NOT REGULATED BY SECTIONS 1510.2
 THROUGH 1510.7 SHALL COMPLY WITH SECTIONS 1510.8.1
 THROUGH 1510.8.5, AS APPLICABLE.
 6. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A
 LINEAR LOAD OF 50 POUNDS PER LINEAR FOOT (PLF) (0.73
 KN/M) IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. GLASS
 HANDRAIL ASSEMBLIES AND GUARDS SHALL ALSO COMPLY WITH
 SECTION 2407.
 7. PLEASE INCREASE THE VALUATION OF THE PROPOSED
 PROJECT TO REFLECT THE ADDITIONAL REQUIREMENTS.
  