Plan Review Notes
Plan Review Notes For Permit 19050721
Permit Number 19050721
Review Stop P
Sequence Number 1
Notes
Date Text
2019-05-21 15:53:36PLUMBING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A CODE COMPLIANT RISER DIAGRAHM.
 PLUMBING RISER - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATION SECTION
 107.3.5.3 (12)
  
 2. PROVIDE PAN FOR WATER HEATER.
 P2801.6REQUIRED PAN.
 WHERE A STORAGE TANK-TYPE WATER HEATER OR A HOT WATER
 STORAGE TANK IS INSTALLED IN A LOCATION WHERE WATER
 LEAKAGE FROM THE TANK WILL CAUSE DAMAGE, THE TANK SHALL
 BE INSTALLED IN A PAN CONSTRUCTED OF ONE OF THE
 FOLLOWING:
 1. 1.GALVANIZED STEEL OR ALUMINUM OF NOT LESS THAN
 0.0236 INCH (0.6010 MM) IN THICKNESS.
 2. 2.PLASTIC NOT LESS THAN 0.036 INCH (0.9 MM) IN
 THICKNESS.
 3. 3.OTHER APPROVED MATERIALS.
  
 3. PROVIDE DETAIL FOR WATER HEATER DISCHARGE.
 P2804.6.1REQUIREMENTS FOR DISCHARGE PIPE.
 THE DISCHARGE PIPING SERVING A PRESSURE-RELIEF VALVE,
 TEMPERATURE RELIEF VALVE OR COMBINATION VALVE SHALL:
 DISCHARGE TO THE FLOOR, TO THE PAN SERVING THE WATER
 HEATER OR STORAGE TANK, TO A WASTE RECEPTOR OR TO THE
 OUTDOORS.
 P2801.6.2PAN DRAIN TERMINATION.
 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER
 A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR SHALL
 EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE
 NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE THAN 24
 INCHES (610 MM) ABOVE THE ADJACENT GROUND SURFACE.
  
 4. PROVIDE DETAIL FOR SHOWER PAN.
 P2709.1 SHOWER PAN CONSTRUCTION.
 P2709.3 SHOWER PAN LINING INSTALLATION.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  