Plan Review Notes
Plan Review Notes For Permit 19050671
Permit Number 19050671
Review Stop B
Sequence Number 1
Notes
Date Text
2019-05-14 08:01:51****CORRECTIONS****
 W.P.B. PERMIT: 19050671
 REVIEWED: MAY 13, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) PROVIDE WRITTEN NARRITIVE OF WORK TO BE DONE TO THE
 MAIN STRUCTURE AND THEN ONE FOR THE GARAGE IF INCLUDED.
 PERMIT IS BASED ON VALUE OF WORK BEING PERFORMED.
 PLEASE PROVIDE A COPY OF THE CONTRACT FOR WORK, OR
 PROVIDE VALUE BASED ON THE NARRITIVE PROVIDED.
  
 2) 107.3.5 FBC[AMENDED] PLEASE PROVIDE DETAILED
 DRAWINGS TO SHOW THE WORK TO BE PERFORMED.
 A DRAWING WITH NOTES TO SHOW DEMOLITION OF AREAS OF
 WORK, DRAWING TO SHOW NEW CONFIGURATIONS,
 3) ALSO, IF ANY WORK BEING DONE TO THE EXTERIOR PROVIDE
 PRODUCT APPROVALS. CHANGES MAY INCLUDE DOORS, WINDOWS,
 ROOFING OR CLADDING.
  
 4) 501 FBC[EXISTING] STATE THE LEVEL OF ALTERATION FOR
 WORK BEING PERFORMED.
 -PLEASE ADD LEVEL OF ALTERATION TO DESIGN DATA.
  
 5) R314.2.2 FBC[R] ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. EXCEPTIONS:
  -REVIEW THIS CODE SECTION (R314.2.2)FOR EXCEPTIONS AND
 LOCATIONS WHERE SMOKE DETECTORS MAY BE REQUIRED.
  
 6) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS:
 GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN
 EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF
 SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED
 PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY
 SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE.
  -PLEASE CHOOSE ENERGY CODE COMPLIANCE METHOD AND SHOW
 HOW NEW WORK WILL COMPLY WITH THE METHOD CHOSEN.
  
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS.
 FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE
 REQUIRED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -FENCE WOULD BE A SEPARATE PERMIT.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  