| 2019-06-03 16:29:00 | ** FAILED ** |
| | |
| | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE |
| | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE |
| | APPLICABLE: |
| | |
| | 1.) A SURVEY OF THE PROPERTY WAS NOT PROVIDED WITH THE |
| | PERMIT SUBMITTAL. PLEASE PROVIDE AS IT IS A REQUIRED |
| | DOCUMENT. |
| | |
| | 2.) LOT DIMENSIONS FROM THE SURVEY SHALL BE PROVIDED IN |
| | THE SITE PLAN FOR CONSISTENCY. |
| | |
| | 3.) THE SITE PLAN HAS A LOT OF OVERLAPPING WHICH MAKES |
| | IT DIFFICULT TO READ THE DIMENSIONS AND OTHER PERTINENT |
| | INFORMATION. PLEASE ENSURE THAT THERE IS NO TEXT |
| | OVERLAP. ADDITIONALLY, THE LANDSCAPING SHOULD NOT BE |
| | PROVIDED IN THE SITE PLAN, AS ANY EXISTING/PROPOSED |
| | LANDSCAPING FOR THE PROJECT SHALL BE REVIEWED AS A |
| | SEPARATE LANDSCAPE PERMIT PRIOR TO THE ISSUANCE OF THIS |
| | PERMIT. |
| | |
| | 4.) SHOW THE SETBACK DISTANCE OF ALL PROPOSED |
| | STRUCTURES (I.E. SWIMMING POOL, DRIVEWAYS, A/C UNIT |
| | PAD, ETC.) TO THE PROPERTY LINES TO ENSURE ALL |
| | STRUCTURES WILL MEET THE MINIMUM SETBACK DISTANCES PER |
| | THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). |
| | |
| | 5.) THE MAXIMUM HEIGHT OF THE BUILDING SHALL NOT EXCEED |
| | 30 FT. THE HEIGHT OF THE BUILDING SHALL BE MEASURED |
| | FROM GRADE OF THE OUTSIDE WALL TO THE MID-HEIGHT LEVEL |
| | BETWEEN THE EAVES AND THE RIDGE FOR GABLE, HOP AND |
| | GAMBREL ROOFS. [ZLDR S.94-72(A)(3)] |
| | |
| | 6.) THE CHIMNEY SHALL NOT EXCEED THE DISTRICT HEIGHT |
| | REQUIREMENTS BY 10%. PLEASE SHOW DIMENSIONS IN THE |
| | ELEVATIONS. [ZLDR S.94-306] |
| | |
| | 7.) THERE SEEMS TO BE SOME EXTERIOR SCREENING PROPOSED |
| | FOR THE WASTE CONTAINERS, EMERGENCY GENERATOR, POOL |
| | EQUIPMENT, ETC.). PLEASE PROVIDE A DETAIL OF THE |
| | PROPOSED SCREENING (I.E. HEIGHT, SETBACK FROM PROPERTY |
| | LINES, ETC.). SUCH FEATURE SHALL ALSO BE ILLUSTRATED IN |
| | THE ELEVATIONS. |
| | |
| | 8.) FLOOR PLANS DO NOT MATCH THE ELEVATIONS. PLEASE |
| | REVIEW AND ADDRESS FOR CONSISTENCY. |
| | |
| | 9.) A CIRCULAR DRIVEWAY SHALL NOT EXCEED 10 FT. IN |
| | WIDTH AT THE PROPERTY LINE FOR EACH DRIVEWAY OPENING. |
| | PLEASE PROVIDE DIMENSIONS FOR COMPLIANCE WITH THE |
| | ZLDRS. [ZLDR S.94-312(1)] |
| | |
| | 10.) PLEASE ENSURE THAT ALL COMPONENTS OF PROPOSED |
| | DRIVEWAY COMPLY WITH THE SETBACK DIMENSIONS OF THE |
| | ZLDRS BY DENOTING THE SETBACK(S) DISTANCE FROM THE |
| | DRIVEWAY TO THE PROPERTY LINE IN THE SITE PLAN (I.E. |
| | PORTION OF THE VEHICULAR TURNAROUND). |
| | |
| | 11.) STRUCTURAL OVERHANGS (I.E. EAVES, ROOF OVERHANGS, |
| | ETC.) SHALL NOT EXTEND MORE THAN 3 FT. INTO ANY |
| | REQUIRED SETBACK. PLEASE SHOW DIMENSIONS FOR COMPLIANCE |
| | WITH THIS REQUIREMENT. [ZLDR S.94-305(B)(2)] |
| | |
| | NOTES: |
| | |
| | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: |
| | LANDSCAPING, HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS), |
| | GENERATOR, ACCESSORY SCREEN ENCLOSURE (I.E. FOR |
| | GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. |
| | |
| | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. |
| | |
| | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| | QUESTIONS. |
| | |
| | * ZONE: SF7 |
| | |