Plan Review Notes
Plan Review Notes For Permit 19050305
Permit Number 19050305
Review Stop P
Sequence Number 1
Notes
Date Text
2019-05-16 14:46:31 
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 1) THE COFFEE AND CASHWRAP SINK ARE NOT SHOWN AS
 ACCESSIBLE AND ARE BOTH LIST AS SNK-2. PROVIDE CLEAR
 FLOOR SPACE AND COUNTER TOP DETAIL SHOWING MAX 34".
 FBC-ACC 606.2, 606.3
  
 2) THE 2 COMPARTMENT SINK LOCATED IN THE CLASS ROOM
 KITCHEN SHALL BE ACCESSIBLE AS IT WOULD BE A COMMON USE
 SINK. PROVIDE CLEAR FLOOR SPACE AND MAX HEIGHT DETAIL
 MAX 34". FBC-ACC 606.2, 606.3
  
 3) WATER HEATER DETAIL IS MISSING THE ANTISIPHON VALVE
 REQUIRED FOR BOTTOM FEED WATER HEATERS. FBC P 504.1
  
 4) PROVIDE HOW YOU SIZED THE INTERCEPTOR EITHER BY FAC
 64E-6 OR BY THE PDI G101? FBC P1003.1. AND WHAT
 MANUFACTURE AND MODEL YOU ARE CALLING FOR. FBC 107.3.5
  
 5) PROVIDE LOCATION ON PLAN OF WHERE GREASE INTERCEPTOR
 IS TO BE INSTALLED. FBC P 1003.2
  
 6) PROVIDE NOTE ON PLAN THAT BACKFLOW'S AND GREASE
 INTERCEPTOR REQUIRED A SEPARATE PERMIT. WPB AMEND 105.1
  
 7) PROVIDE INSTALLATION MANUAL/ SPECIFICATION SHEETS
 FOR THE SOFTENER SYSTEM AND GREASE INTERCEPTOR. FBC
 107.2.1
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  
  