2019-05-20 14:32:03PLUMBING 1ST REVISION REVIEW**DENIED**
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 1) YOU CALL OUT ALL RESTROOMS AS UNISEX. THE ONLY
 RESTROOM PERMITTED TO BE UNISEX IS THE WAREHOUSE
 RESTROOM AS THE OCCUPANT LOAD IS UNDER 16 PER 403.2.
 LABEL EACH OF THE OTHER RESTROOM'S AS MEN'S OR WOMENS.
  
 2) RESTROOM # 108 WAS REDLINE PROVISO ON APPROVED PLAN
 MUST COMPLY WITH ADA. THIS REVISION IS ONLY CALLING FOR
 GRAB BAR REINFORCEMENT IS STILL SHOWING TOO SMALL @ 7'
 TO MEET MIN ADA. PROVIDE CLEAR FLOOR SPACE, TURNING
 SPACE, CHANGE DOOR SO NOT TO SWING INTO THE SINKS CLEAR
 FLOOR SPACE. FBC-ACC 604.3, 603.2.1, 603.2.3
  
 3) SHOW RESTROOMS 106 AND 107 CLEAR FLOOR SPACE AND
 TURNING SPACE. FBC-ACC 604.3, 603.2.1
  