Plan Review Notes
Plan Review Notes For Permit 19040938
Permit Number 19040938
Review Stop B
Sequence Number 3
Notes
Date Text
2019-09-23 14:49:42****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. PLAN TO BE REVISED TO NOTE COMPLIANCE WITH FBC 2017;
 REMOVE REFERENCES TO PREVIOUS CODES AND STAFF.
  
 2ND REVIEW: THIS WAS DONE, BUT THE FOLLOWING ISSUES
 WERE FOUND:
  
 LS1, BUILDING CODE SUMMARY 2, SEE FBC B 602.4, THIS
 BUILDING IS NOT HEAVY TIMBER TYPE IVB, REVISE.
 LS1, BUILDING CODE SUMMARY 5, SEE FBC B 302, EACH AREA
 IS TO BE CLASSIFIED AS TO OCCUPANCY CLASSIFICATION
 ("MIXED" IS NOT ONE OF THE CLASSIFICATIONS). THIS
 APPEARS TO BE BUSINESS AND A3 ON THE FIRST FLOOR, R2 ON
 THE SECOND FLOOR. REVISE SECTION 5 TO CLARIFY.
 LS1, BUILDING CODE SUMMARY 6, PROPOSED HEIGHT IS 1
 STORY; ISN'T THIS A 2 STORY BUILDING?
 LS1, BUILDING CODE SUMMARY 7, FLOOR CONSTRUCTION IS 0
 HOURS. AN OCCUPANCY SEPARATION BETWEEN RESIDENTIAL AND
 OTHER OCCUPANCIES IS REQUIRED AND WAS REQUIRED WHEN THE
 BUILDING WAS CONSTRUCTED, REVISE TO REFLECT SEPARATION
 REQUIREMENT.
  
 2-3. OK
  
 4. ONE BATHROOM ON THE 1ST FLOOR IS NOT ACCESSIBLE AND
 THE ENTRY DOORS TO THE MEDITATION ROOM ARE NOT
 ACCESSIBLE; APPLICANT TO DOCUMENT THAT THIS IS NOT
 REQUIRED DUE TO DISPROPORTIONATE COST. THIS MAY BE SENT
 VIA EMAIL FOR PRELIMINARY REVIEW.
  
 2ND REVIEW, IT IS NOT CLEAR HOW THIS WAS ADDRESSED.
  
 5-9. OK
  
 10. LIFE SAFETY AND ARCHITECTURAL SHEETS TO BE PREPARED
 BY AN ARCHITECT OR ENGINEER WILL OBTAIN A DETERMINATION
 FROM FBPE OR FLORIDA BOARD OF ARCHITECTS.
  
 2ND REVIEW, IT IS NOT CLEAR HOW THIS WAS ADDRESSED.
  
  
  