Plan Review Notes
Plan Review Notes For Permit 19040938
Permit Number 19040938
Review Stop G
Sequence Number 2
Notes
Date Text
2019-09-21 13:28:00 
 2ND REVIEW: 19041429
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 GAS COMMENTS:
  
 1. WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS PART OF
 THE APPLIANCE, A SEDIMENT TRAP SHALL BE INSTALLED
 DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO
 THE INLET OF THE APPLIANCE AS PRACTICAL.PER FBC FG
 408.4
  
 2. PIPING INSTALLED OUTDOORS SHALL BE ELEVATED NOT LESS
 THAN 31/2 INCHES (89 MM) ABOVE GROUND AND WHERE
 INSTALLED ACROSS ROOF SURFACES, SHALL BE ELEVATED NOT
 LESS THAN 31/2 INCHES (89 MM) ABOVE THE ROOF SURFACE.
 PIPING INSTALLED ABOVE GROUND, OUTDOORS, AND INSTALLED
 ACROSS THE SURFACE OF ROOFS SHALL BE SECURELY SUPPORTED
 AND LOCATED WHERE IT WILL BE PROTECTED FROM PHYSICAL
 DAMAGE. WHERE PASSING THROUGH AN OUTSIDE WALL, THE
 PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING
 OR WRAPPING WITH AN INERT MATERIAL. WHERE PIPING IS
 ENCASED IN A PROTECTIVE PIPE SLEEVE, THE ANNULAR SPACE
 BETWEEN THE PIPING AND THE SLEEVE SHALL BE SEALED.PER
 FBC FG 404.9
  
 3. GALVANIZED PIPING SHALL NOT RUN UNDERGROUND UNLESS
 IT IS SLEEVED. PER FBC FG 404.11
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  