| Date |
Text |
| 2019-04-30 09:43:46 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19040601 |
| | ADD: 2465 MERCER AVENUE, UNIT 202 |
| | CONT: CHANDLER |
| | TEL: 561-791-6934 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. APRIL 30/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) THE COVERSHEET G001 UNDER THE HEADING, GOVERNING |
| | MUNICIPALITY: CITY OF LAUDERDALE LAKES, PLEASE CORRECT |
| | TO CITY OF WEST PALM BEACH. 107.2.1.2 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 2) THE FLOOR PLAN, A-102 INDICATES A NEW BREAK ROOM |
| | WITH ONLY 2 FOOT 8 INCHES IN FRONT OF THE BREAK ROOM |
| | SINK. PLEASE REVIEW THE 2017 FBC-ACCESSIBILITY CODE |
| | SECTION 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE |
| | COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH, |
| | AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE |
| | PROVIDED. |
| | EXCEPTIONS: |
| | 1. A PARALLEL APPROACH COMPLYING WITH 305 SHALL BE |
| | PERMITTED TO A KITCHEN SINK, IN A SPACE WHERE A COOK |
| | TOP OR CONVENTIONAL RANGE IS NOT PROVIDED, AND TO WET |
| | BARS. |
| | PLEASE NOTE IF THE PARALLEL APPROACH METHOD IS USED THE |
| | SINK CANNOT BE IN THE CORNER. THE 48 INCH CLEAR FLOOR |
| | SPACE WOULD NEED TO BE CENTERED ON THE SINK. |
| | |
| | 3) SHEET A-501 TYPICAL CABINET BRACING DETAIL DOES NOT |
| | PROVIDE THE HEIGHT OF THE BREAK ROOM CABINET NOR THE |
| | HEIGHT OF THE LIP OF THE SINK. PLEASE SHOW COMPLIANCE |
| | WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION |
| | 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED |
| | WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER |
| | SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 4) SHEET A201 SHOWS A NEW ACCESSIBLE RESTROOM WITH ONE |
| | DIMENSION 7 FEET 8 INCHES, BUT THE PLAN DOES NOT GIVE |
| | THE DIMENSION OF THE BACK WALL, NOR DOES THE PLAN SHOW |
| | THE DIMENSION OF THE WATER CLOSET TO THE NEAREST SIDE |
| | WALL NOR THE LAV TO THE NEAREST SIDE WALL. SHOW |
| | COMPLIANCE WITH THE 2017 ACCESSIBILITY CODE SECTIONS: |
| | 604.3 CLEARANCE. CLEARANCES AROUND WATER CLOSETS AND IN |
| | TOILET COMPARTMENTS SHALL COMPLY WITH 604.3. |
| | |
| | 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| | 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM |
| | THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| | PERPENDICULAR FROM THE REAR WALL. |
| | |
| | 604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND THE |
| | WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER |
| | CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY |
| | NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE |
| | ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT |
| | OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER |
| | FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE |
| | REQUIRED WATER CLOSET CLEARANCE. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |