| Date |
Text |
| 2019-06-05 08:16:55 | ***CORRECTIONS*** |
| | PETER E VALENTI |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6673 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | PROVIDE THE FOLLOWING INFORMATION FOR FLOORING |
| | SUBMITTALS: |
| | |
| | 1. FLOOR PLAN WITH DIMENSIONS AND LOCATION OF WORK. |
| | > DESIGNER TO PRINT NAME AND SIGN PLAN PER FBC 107. |
| | 2. TOTAL SQUARE FOOTAGE OF NEW FLOORING. |
| | 3. TYPE OF PROPOSED HARD FLOORING (TILE, LAMINATE, |
| | WOOD, MARBLE, ETC.). |
| | 4. STATED VALUE OF WORK. |
| | 5. DESCRIPTION OF EXISTING SITE CONDITIONS: |
| | (A) THICKNESS OF SLAB (B) FLOOR/CEILING ASSEMBLY BELOW |
| | (EXPOSED CONCRETE, SUSPENDED GYPSUM OR ACOUSTICAL ). |
| | 6. PROPOSED UNDERLAYMENT. |
| | 7. TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON |
| | THE EXISTING SITE CONDITIONS. |
| | 8. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S: |
| | E-84, E-90 & E-492. |
| | 9. ALL DOCUMENTS SHALL BE SUBMITTED IN DUPLICATE. |
| | |
| | FBC 603.1 FLAME SPREAD - ASTM E 84-09 |
| | |
| | FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | |
| | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | |
| | SUBMIT TWO COPIES OF THE TEST REPORTS FOR THE SOUND |
| | INSULATION INCLUDING FLAME SPREAD AND SMOKE DEVELOPED |
| | FOR THE APPLICABLE CONSTRUCTION CONDITIONS. |
| | |