| Date |
Text |
| 2019-05-08 16:22:25 | 1ST REVIEW: 19040465 |
| | |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHT. CHLS-0.1.1 THE RESTROOM FIXTURE COUNT IS |
| | CALLING OUT A TOTAL OF 10 TOILETS FOR WOMEN BUT I ONLY |
| | COUNT 9 ON THE PLAN PLEASE CLARIFY 10 IS THE REQUIRED |
| | NUMBER. PER FBC PL TABLE 403.1 AND WPB AMEND TO FBC |
| | 107.2.1 |
| | |
| | 2. SHT. CH-5.3 SHOW CLEAR FLOOR SPACE FOR THE TOILET |
| | AND WATER FOUNTAIN FOR FORWARD APPROACH. PER FBC ACC |
| | 604.3.1, 602.2 |
| | |
| | 3. SHT. CH-5.3 THE ACCESSIBILITY NOTE ARE CALLING OUT |
| | FAC 2014 5TH EDITION THE COMPLIANT CODE SHALL BE FBC |
| | ACC 1017 6TH EDITION. WPB AMEND TO FBC 107.2.1 |
| | |
| | 4. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL |
| | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE |
| | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING |
| | SURFACE. FBC ACC 609.4 |
| | |
| | 5. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG |
| | MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL |
| | AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. FBC |
| | ACC 604.5.1 |
| | |
| | 6. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG |
| | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| | CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES |
| | MINIMUM ON THE OTHER SIDE. FBC ACC 604.5.2 |
| | |
| | 7. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS |
| | SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE |
| | REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES |
| | OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE |
| | OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE |
| | FINISH FLOOR OR GROUND. FBC ACC 603.3 |
| | |
| | 8. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT |
| | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE |
| | DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15 |
| | INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH |
| | FLOOR. FBC ACC 604.7 |
| | |
| | 9. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| | FLOOR SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM |
| | MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE |
| | SPRUNG TO RETURN TO A LIFTED POSITION. FBC ACC 604.4 |
| | |
| | 10. ON THE FLOOR PLANS THE SANITARY PIPING IS SHOWN AS |
| | A DASHED LINE THE PLUMBING LEGEN SHWS A DASHED LINE AS |
| | A VENT PLEAS CLARIFY AND LABEL ALL PIPING. PER WPB |
| | AMEND TO FBC 107.2.1 |
| | |
| | 11. SHT. P-3.0 PLEASE LABEL ENLARGE ISOMETRIC DRAWING. |
| | PER WPB AMEND TO FBC 107.2.1 |
| | |
| | 12. SHT. P-3.0.1, 3.1.1, P-3.1 P3.0 LABEL THE ENDS OF |
| | THE PIPE TO MATCH UP TO OTHER END WPB AMED TO FBC |
| | 107.2.1 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |