| Date |
Text |
| 2019-06-24 08:56:46 | BUILDING REVIEW COMMENTS |
| | W.P.B. PERMIT: 19040464 |
| | 2 ND REVIEW: JUNE 24, 2019 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[B] = FBC BUILDING |
| | FBC[A] = FBC ACCESSIBILITY |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | |
| | 5)319 FBC[R] ADDRESSES ARE NEEDED FOR THIS PROJECT. THE |
| | PERMIT CANNOT BE ISSUED UNTIL AND ADDRESS HAS BEEN |
| | ASSIGNED TO THE BUILDING. |
| | - PLEASE CALL MICHAEL ORIO BY PHONE AT 561-494-1080, OR |
| | BY E-MAIL [email protected] |
| | REPONSE SAYS ADDRESS IS ON SITE PLAN. |
| | - I DON'T SEE THE BUILDING ADDRESS ON SD-4. |
| | WHAT IS THE ADDRESS ASSIGNED BY MICHAEL ORIO FOR THIS |
| | SPECIFIC BUILDINGH? THE PERMIT ADDRESS IN OUR SYSTEM |
| | NEEDS TO MATCH THE ASSIGNED BUILDING ADDRESS BEFORE THE |
| | PERMIT IS ISSUED. |
| | |
| | 6) REQUIREMENT 2 - ACCESSIBLE AND USABLE PUBLIC AND |
| | COMMON USE AREAS |
| | - SHOW ACCESSIBLE PATH TO TRASH COLLECTION AREA. |
| | - RESPONSE SAYS SEE LS-0.4.1. THIS IS NOT A SITE PLAN |
| | AND THE PATH CAN'T BE SEEN TO THE TRASH AREA IN THE |
| | PARKING LOT. PLEASE SHOW ACCESSIBLE PATH ON PLAN THAT |
| | WILL SHOW THE PATH AND HOW IT RELATES TO THE SITE. |
| | |
| | 9) 1011.12 FBC[B] |
| | - ROOF HATCH OK SINCE NO MECHANICAL ACCESS. |
| | 1011.12.2 FBC[B] SHEET A-2.4.6 SHOWS 30 X 36 INCH BILCO |
| | HATCH. PLEASE DIMENSION THE ROOF HATCH TO SHOW IT IS 16 |
| | SQ. FT MINIMUM. MINIMUM WIDTH SHOULD ALLOW FOR |
| | EQUIPMENT REPLACEMENT. |
| | NEW COMMENT: |
| | 1011.12.1, IN BUILDINGS WITHOUT AN OCCUPIED ROOF ACCESS |
| | TO THE ROOF FROM THE TOP STORY SHALL BE PERMITTED TO BE |
| | BY AN ALTERNATING TREAD DEVICE, A SHIPS LADDER OR A |
| | PERMANENT LADDER. |
| | - HOW IS THE ROOF HATCH ACCESSED? |
| | |
| | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| | [email protected] |
| | |
| | |
| | |