2019-05-28 07:45:16****CORRECTIONS****
 W.P.B. PERMIT: 19040464
 REVIEWED: MAY 28, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH
 ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES
 TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH
 THE PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND
 THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR
 GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS
 ORDINANCE. PER CITY OF WEST PALM BEACH ORDINANCE NO.
 4504-14, AND CITY OF WEST PALM BEACH CODE OF
 ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION
 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS
 1% OF THE TOTAL PROJECT CONSTRUCTION COST. PER CITY OF
 WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, ART IN
 PUBLIC PLACES, SECTION 78-122, RENOVATION AND NEW
 CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO THE
 ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS. SEC. 78-129. - PUBLIC ART ASSESSMENT FOR
 PRIVATE DEVELOPMENT. (A) APPLICABILITY. THE PROVISIONS
 OF THIS ARTICLE AND THE PUBLIC ART ASSESSMENT SECTION
 SHALL APPLY TO ALL PRIVATE DEVELOPMENT PROJECTS,
 INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR
 IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL
 CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000.00. ALL BUILDINGS WITHIN NEW PLANNED
 DEVELOPMENTS SHALL BE ASSESSED CUMULATIVELY TOWARDS
 THIS ART IN PUBLIC PLACES REQUIREMENT, EVEN IF THE
 BUILDINGS ARE PERMITTED SEPARATELY OR DEVELOPED IN
 PHASES. THE PROVISIONS OF THIS SECTION APPLY TO NEW
 DEVELOPMENT OR NEW CONSTRUCTION WITHIN EXISTING PLANNED
 DEVELOPMENTS.
 - THIS PROJECT MEETS THE CRITERIA TO PROVIDE AIPP.
 PLEASE CONTACT: MS. SYBILLE WELTER ART IN PUBLIC PLACES
 COORDINATOR 822-1515 E-MAIL: [email protected]
  
 2) 109.3 FBC[AMENDED] PROVIDE COST ESTIMATING METHOD
 AND CALCULATIONS THAT WERE USED FOR PERMIT VALUATION.
 - THE VALUE APPEARS TO BE BASED AT AROUND 100 DOLLARS
 PER SQUARE FOOT. CURRENT CONSTRUCTION COSTS FOR ANY
 TYPE OF NEW CONSTRUCTION WOULD EXCEED THAT AMOUNT.
 PLEASE EVALUATE CONSTRUCTION COSTS. THE COSTS WOULD
 EXCLUDE LAND AND ITEMS THAT WILL BE PERMITTED SEPARATLY
 (FIRE ALARM AND FIRE SPRINKLERS)
  
 3) 107.5.3 FBC[AMENDED] CODE EDITIONS.
 - SHEET LS-0.4.0 JUST BELOW FAIR HOUSING EDITION.
 PLEASE REMOVE REFERENCES TO FT. LAUDERDALE.
  
 4) F.S. 553.79(5) THRESHOLD BUILDING.
 THIS PROJECT MEETS THE DEFINITION OF A THRESHOLD
 BUILDING. THE FOLLOWING IS REQUIRED PRIOR TO
 COMMENCEMENT.
 A) COMPLETE THE THRESHOLD / SPECIAL INSPECTOR AGREEMENT
 OF UNDERSTANDING; IF PDF OF AGREEMENT IS NEEDED PLEASE
 CONTACT THE BUILDING PLAN REVIEWER AND THEY WILL
 PROVIDE VIA E-MAIL. [email protected]
 B) PROVIDE RESUMES AND COPIES OF LICENSES FOR ALL
 PROPOSED INSPECTORS. PLEASE INCLUDE AS MANY ADDITIONAL
 INSPECTORS AS POSSIBLE BECAUSE THESE ARE THE ONLY
 PEOPLE THAT THE CHIEF BUILDING INSPECTOR WILL ALLOW TO
 BE ON-SITE.
 C) ALL PLANS ARE TO INCLUDE THE THRESHOLD STATEMENT
 REQUIRED BY FS553.79(7)(D). ?ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECTS OR ENGINEERS
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE
 FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL
 AUTHORITY IN ACCORDANCE WITH THIS CHAPTER 553 AND
 CHAPTER 633.?
 D) OK-FOUND SHEET S-1.1 THRESHOLD INSPECTION PLAN
 REQUIRED, FS553.79(5)A).
 - THERE IS A SIMILAR STATEMENT LIKE ITEM C IN THE
 COMMENT ABOVE, BUT IT NEEDS TO BE THE STATEMENT IN
 QUOTES FROM ITEM C ABOVE.
  
 5)319 FBC[R] ADDRESSES ARE NEEDED FOR THIS PROJECT. THE
 PERMIT CANNOT BE ISSUED UNTIL AND ADDRESS HAS BEEN
 ASSIGNED TO THE BUILDING.
 - PLEASE CALL MICHAEL ORIO BY PHONE AT 561-494-1080, OR
 BY E-MAIL [email protected]
  
 6) REQUIREMENT 2 - ACCESSIBLE AND USABLE PUBLIC AND
 COMMON USE AREAS
 - SHOW ACCESSIBLE PATH TO TRASH COLLECTION AREA.
  
 7) REQUIREMENT 3 - USABLE DOORS. THE DOORS IN COMMON
 SPACES AND THE SIDE ENTERING INTO DWELLING UNITS NEED
 TO HAVE USABLE HARDWARE THAT CAN BE USED WITHOUT TIGHT
 GRASPING OR TWISTING.
 - TYPICALLY THE HARDWARE WOULD BE A LEVER TYPE. THIS
 TYPE OF HARDWARE WOULD NOT BE REQUIRED ONCE INSIDE THE
 UNIT. YOU MAY WANT TO CLARIFY HARDWARE ON THE DOOR
 SCHEDULE.
  
 8) REQUIREMENT 5 - LIGHT SWITCHES, OUTLETS, THERMOSTATS
 AND OTHE CONTROLS IN ACCESSIBLE LOCATIONS. (SIDE
 REACHES OVER OBSTRUCTIONS)
 - PLEASE VERIFY THAT A NOTE OR REFERENCE TO THE
 REQUIRED HEIGHTS CAN BE FOUND IN ELECTRICAL PAGES WHERE
 THE CONTRACTOR WILL SEE THEM.
  
 9) 1011.12 FBC[B] STAIRWAY TO ROOF. IN BUILDINGS FOUR
 OR MORE STORIES ABOVE GRADE PLANE, ONE STAIRWAY SHALL
 EXTEND TO THE ROOF SURFACE UNLESS THE ROOF HAS A SLOPE
 STEEPER THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL
 (33-PERCENT SLOPE).
 - PROVIDE STAIRWAY TO ROOF, OR PROVIDE CODE SECTION
 THAT EXEMPTS 1011.12 FOR BUILDINGS OVER 4 STORIES.
  
 10) 401.4 FBC[R] PROVIDE SOIL REPORT TO SHOW BEARING
 CAPACITY AND FOUNDATION RECOMMENDATIONS.
 - PLEASE UPLOAD GEOTECHNICAL REPORT INTO SUPPORTING
 DOCUMENTS IN PROJECTDOX
  
 11) 107.3.5 FBC[AMENDED]
 - STRUCTURAL S-2.4.1 NOTE 1 SHOULD NOT REFERENCE NAVD
 SINCE IT CONFLICTS WITH CIVIL PLANS. JUST A REFERENCE
 TO SEE CIVIL PLANS WOULD SUFFICE.
  
 12) 1803.6 FBC[B] REPORTING. WHERE GEOTECHNICAL
 INVESTIGATIONS ARE REQUIRED, A WRITTEN REPORT OF THE
 INVESTIGATIONS SHALL BE SUBMITTED TO THE BUILDING
 OFFICIAL BY THE PERMIT APPLICANT AT THE TIME OF PERMIT
 APPLICATION. THIS GEOTECHNICAL REPORT SHALL INCLUDE,
 BUT NEED NOT BE LIMITED TO, THE FOLLOWING INFORMATION:
 - (SEE 1803.6 FOR REQUIREMENTS)
  
 13) 3002.4 FBC[B] ELEVATOR CAR TO ACCOMMODATE AMBULANCE
 STRETCHER. ANY BUILDING THAT IS MORE THAN THREE STORIES
 HIGH OR IN WHICH THE VERTICAL DISTANCE BETWEEN THE
 BOTTOM TERMINAL LANDING AND THE TOP TERMINAL LANDING
 EXCEEDS 25 FEET (7620 MM), MUST BE CONSTRUCTED TO
 CONTAIN AT LEAST ONE PASSENGER ELEVATOR THAT IS
 OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE DEPARTMENT
 EMERGENCY ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL
 BE OF SUCH A SIZE AND ARRANGEMENT TO ACCOMMODATE AN
 AMBULANCE STRETCHER 24 INCHES BY 76 INCHES (610 MM BY
 1950 MM) WITH NOT LESS THAN 5-INCH (127 MM) RADIUS
 CORNERS, IN THE HORIZONTAL, OPEN POSITION AND SHALL BE
 IDENTIFIED BY THE INTERNATIONAL SYMBOL FOR EMERGENCY
 MEDICAL SERVICES (STAR OF LIFE). THE SYMBOL SHALL BE
 NOT LESS THAN 3 INCHES (76 MM) IN HEIGHT AND SHALL BE
 PLACED INSIDE ON BOTH SIDES OF THE HOISTWAY DOOR FRAME.
 - SHOW HOW STRECHER WILL FIT IN ONE OF THE ELEVATORS. A
 SGRAPHIC REPRESENTAION OF 24X74 INCH RECTANGLE WITH
 MAXIMUM 5 INCH RADIUS CORNERS FROM ENTRY TO FINAL
 POSITION ON PLAN VIEW WILL SUFFICE.
  
 14) 107.3.4.1 FBC[AMENDED] DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
 - PLEASE PROVIDE A LIST OF DEFERRED SUBMITTALS SO THAT
 I WILL NOT ASK FOR ITEMS THAT WILL BE SUPPLIED AT A
 LATER DATE, OR INDICATE WHICH PAGE A LIST CAN BE FOUND.
  
 15) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS
 FOR WINDOWS, WINDOW MULL (IF APPLICABLE), DOORS,
 TRANSOMS, SLIDERS OR INDICATE THAT YOU WOULD LIKE THEM
 DEFERED.
  
 16) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT
 APPROVAL(P.A.) FOR ROOFING, OR INDICATE THAT YOU WOULD
 LIKE THEM DEFERED. INCLUDE P.A. FOR RIDGE VENTS IN
 ROOFING SUBMITTAL
  
 17) 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS
 TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
 - THE TRUSS SUBMITTAL CAN BE APPROVED NOW IF PUT IN
 SUPPORTING DOCUMENTS AS A SUBMITTAL, OR IT CAN BE
 DEFERRED. IF DEFERED THE TRUSS PACKAGE NEEDS TO BE
 REVIEWED BY BUILDING INSPECTOR PRIOR TO INSTALLATION.
  
 18) 107.2.1.2 FBC[AMENDED] PROVIDE STAIRCASE AND GUARD
 RAIL ENGINEERING, OR INDICATE THAT IT WILL BE DEFERRED.
  
 19) 1014 FBC [B] GUARDS AND HANDRAILS. 1607.8 FBC [B]
 LOADS ON HANDRAILS AND GUARDRAILS. PROVIDE HANDRAIL AND
 GUARDRAIL ENGINEERING, OR INDICATE THAT YOU WOULD LIKE
 IT DEFERRED.
  
 20) 107.3.4. FBC[AMENDED] A CONSTRUCTION GUARDRAIL
 DETAIL, PREPARED BY A DESIGN PROFESSIONAL LICENSED
 UNDER FS471 OR FS481, IS REQUIRED TO BE SUBMITTED,
 REVIEWED AND ISSUED BY THE CITY OF WEST PALM BEACH, OR
 INDICATE THAT IT WILL BE DEFERRED. *SUBJECT TO THE
 INSPECTORS DISCRETION, THIS MAY BE ACCEPTED IN THE
 FIELD AT TIME OF INSPECTION.
  
 21) 1207.2 FBC[B] PLEASE ADVISE ,VIA EMAIL, WHAT
 FLOORING AND UNDERLAYMENT ARE PROPOSED? IF THE
 UNDERLAYMENT PRODUCT PROPOSED IS NOT ONE FOR WHICH WE
 HAVE TEST REPORTS ON FILE, THE FOLLOWING REPORTS WILL
 BE REQUIRED:
 1207.2 FBC[B] AIR-BORNE SOUND. WALLS, PARTITIONS AND
 FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS AND
 SLEEPING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS OF
 NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED,
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E90.
 1207.3 FBC[B] STRUCTURE-BORNE SOUND. FLOOR/CEILING
 ASSEMBLIES BETWEEN DWELLING UNITS AND SLEEPING UNITS OR
 BETWEEN A DWELLING UNIT OR SLEEPING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS RATING OF NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED, WHEN TESTED IN
 ACCORDANCE WITH ASTM E492.
 603.1 FBC[B] ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
 22) 804.1 FBC[B] GENERAL. INTERIOR FLOOR FINISH AND
 FLOOR COVERING MATERIALS SHALL COMPLY WITH SECTIONS
 804.2 THROUGH 804.4.2. EXCEPTION: FLOOR FINISHES AND
 COVERINGS OF A TRADITIONAL TYPE, SUCH AS WOOD, VINYL,
 LINOLEUM OR TERRAZZO, AND RESILIENT FLOOR COVERING
 MATERIALS THAT ARE NOT COMPRISED OF FIBERS.
  
 103.1.1.2 FBC[CE] CODE COMPLIANCE CERTIFICATION. THE
 BUILDINGS OWNER, THE OWNERS ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
  -PLEASE HAVE APPROPRIATE PARTIES SIGN THE ENERGY
 CALCULATIONS.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  