| Date |
Text |
| 2019-06-13 11:21:27 | 3RD REVIEW FBC-2017 MECHANICAL |
| | PERMIT #19040317 |
| | 5/13/19 |
| | |
| | APPLICABLE CODES IN EFFECT: |
| | |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) INSULATION INSTALLED ON A SUSPENDED CEILING WITH |
| | REMOVABLE CEILING TILES SHALL NOT BE CONSIDERED PART OF |
| | THE MINIMUM THERMAL RESISTANCE OF THE ROOF INSULATION- |
| | SECTION C402.2.2 FBC EC. THE SUBMITTED INPUT DATA |
| | REPORT ATTACHED TO THE ENERGYGAUGE COMPLIANCE REPORT |
| | SHOWS R-11 IN THE MTL BLDG ROOF WHICH DOES NOT |
| | REPRESENT THE ACTUAL FIELD CONDITIONS. IN ADDITION, |
| | PLEASE REVIEW THE 2015 IECC COMMENTARY REGARDING |
| | INSULATION ON THE UPPERSIDE OF THE CEILING TILES: "THE |
| | CODE PROHIBITS CONDIDERING TH INSULATION ON THE UPPER |
| | SIDE OF REMOVABLE CEILING TILES AS A PORTION OF THE |
| | REQUIRED INSULATION. THEREFORE, ON SUSPENDED CEILING |
| | SYSTEMS WITH REMOVABLE TILES, ANY INSULATION INSTALLED |
| | AT THIS LOCATION IS NOT CONSIDERED AS CONTRIBUTING TO |
| | THE MINIMUM REQUIRED BUILDING THERMAL ENVELOPE |
| | PROVISIONS." |
| | IN ORDER TO ADDRESS THIS SITUATION, IT APPEARS |
| | INSULATION WOULD BE CREDITIED IF IS INSTALLED ABOVE A |
| | HARD CEILING, OR IF THE WALLS AND THERMAL BARRIERS |
| | EXTENDED UP TO THE ROOF DECK AND THE ROOF WAS INSULATED |
| | TO MINIMUM R-10. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| | KEEP THEM WITH THE SUBMITTALS. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |