| 2019-08-19 18:09:46 | REVISION, SECOND BUILDING REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014) AND CITY AMENDMENTS. |
| | |
| | ORIGINAL COMMENT: |
| | 1- ARCHITECT STATES ON SHEET A-02 THAT "THIS KITCHEN |
| | SHALL BE USED AS A DOMESTIC KITCHEN FOR USE BY |
| | INDIVIDUAL PATIENTS & GUESTS AS WELL AS FOR THE |
| | PURPOSES OF STORING AND HEATING FOOD PREPARED OFFSITE. |
| | NO FOOD SHALL BE PREPARED FOR PUBLIC CONSUMPTION IN |
| | THIS KITCHEN". |
| | |
| | A)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING |
| | KITCHEN COMPLIANCE WITH SEC. 804 FBC-ACCESSIBILITY AS |
| | REQUIRED BY SEC. 212 FBC-ACCESSIBILITY. |
| | |
| | RESPONSE: |
| | (1) SEC. 804.2.2 FBC-ACCESSIBILITY FOR U-SHAPED |
| | KITCHENS REQUIRES 60" CLEARANCE BETWEEN ALL OPPOSING |
| | BASE CABINETS, COUNTER TOPS, APPLIANCES OR WALL WITHIN |
| | KITCHEN WORK AREAS. PLEASE REVISE PLANS AS REQUIRED. |
| | |
| | (2) PLEASE SHOW THE KITCHEN WORK SURFACE POSITIONED FOR |
| | A FORWARD APPROACH AS REQUIRED BY SEC. 804.3.1 |
| | FBC-ACCESSIBILITY. ALSO, SHOW KNEE AND TOE CLEARANCE |
| | COMPLYING WITH SEC. 306 FBC-ACCESSIBILITY. AND SPECIFY |
| | THE HEIGHT OF THE KITCHEN WORK SURFACE AS REQUIRED BY |
| | SEC. 804.3.2 FBC-ACCESSIBILITY |
| | |
| | (3) THE LOCATION OF THE MICROWAVE ABOVE THE COOKTOP |
| | DOESN'T SEEM TO COMPLY WITH SEC. 308.3.2 |
| | FBC-ACCESSIBILITY FOR SIDE REACH WITH AN OBSTRUCTION. |
| | PLEASE, REVISE AS REQUIRED. |
| | |
| | (4) PROVIDE INFORMATION SHOWING THE HEIGHT OF THE SINK |
| | AS REQUIRED BY SEC. 804.4 AND SEC. 606.3 |
| | FBC-ACCESSIBILITY |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND |
| | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. |
| | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD |
| | DRAWINGS/DOCUMENTS FOR REFERENCE. |
| | |
| | |
| | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE |
| | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| | COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |