Plan Review Notes
Plan Review Notes For Permit 19040126
Permit Number 19040126
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2019-05-15 09:18:54THIS BUILDING IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA. THE FLOOD ZONE IS AE AND THE BFE IS 12.1' NAVD
 88. THE CITY OF WEST PALM BEACH FLOOD ORDINANCE
 REQUIRES A TWO (2) FOOT FREE BOARD. ALL NEW
 CONSTRUCTION OR SUBSTANTIALLY IMPROVEMENTED EXISTING
 BUILDINGS ARE REQUIRED TO COMPLY WITH THE CITY'S FLOOD
 ORDINANCE AND EITHER BE RAISED TO OR ABOVE THE BFE PLUS
 TWO FEET OR COMMERCIAL BUILDINGS CAN BE DRY FLOOD
 PROOFED. THE PROPOSED IMPROVEMENT ($835,735.00) APPEARS
 TO BE A SUBSTANTIAL IMPROVEMENT BASED ON PROPERTY
 APPRAISER VALUATION FOR THE STRUCTURE ($456,220.00). IF
 THIS IS A SUBSTANTIAL IMPROVEMENT, THE STRUCTURE IS TO
 BE BROUGHT INTO COMPLIANCE (BFE 12.1' + 2'=14.1' NAVD88
 FOR FINISHED FLOOR, ALL MECHANICAL EQUIPMENT).
 APPLICANT MAY PROVIDE DOCUMENTATION FOR VALUATION OTHER
 THAN PROPERTY APPRAISER; PLEASE SEE FEMA TECHNICAL
 BULLETIN 758, SECTION 4.5:
  
 HTTPS://WWW.FEMA.GOV/MEDIA-LIBRARY-DATA/20130726-1734-2
 5045-2915/P_758_COMPLETE_R3.PDF
  
  