Plan Review Notes
Plan Review Notes For Permit 19031379
Permit Number 19031379
Review Stop P
Sequence Number 1
Notes
Date Text
2019-04-09 13:39:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL
 MANUAL
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. SP SANITARY RISER DIAGRAM AND 1B FLOOR PLAN
 A. PER FBC PL 701.3 AND FBC RES P2601.1, THE SANITARY
 BUILDING DRAIN SHALL CONNECT TO A COMMON BUILDING SEWER
 FOR ITSELF AND THE MAIN HOUSE AND SHALL NOT DISCHARGE
 THROUGH THE MAIN HOUSE BUILDING DRAIN.
 B. GUEST HOUSE FLOOR PLAN SHOWS A SINK. SANITARY RISER
 DOES NOT SHOW THE SINK. PER WPB FBC 107.2.1, SHOW SINK
 ON SANITARY RISER AND CONNECT DOWNSTREAM OF BATHROOM
 GROUP PER FBC RES P3108.1.
 2.PER WPB FBC 107.2.1, SHOW HOW HOT WATER SHALL BE
 SUPPLIED IN COMPLIANCE WITH FBC PL 607.1 AND FBC RES
 P2601.1
  
  
 END OF COMMENTS
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715