| Plan Review Notes For Permit 19030966 |
| Permit Number |
19030966 |
|
| Review Stop |
M |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2019-04-11 12:42:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030966 | | | 4/11/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO SECTION 61G15-23.002 FAC: THE ASHRAE-90 | | | 2013 COMPLIANCE DATA REPORT FOR THE WALK-IN FREEZER | | | SHALL BE SIGNED AND SELAED BY THE ENGINEER WHO | | | POREPARED THE DOCUMENT- RANDY HERBERT. | | | | | | 2) INDICATE HOW THE OUTDOOR WALK-IN FREEZER WILL BE | | | PROTECTED FROM DAMAGE SUCH AS VEHICLE IMPACT- SECTION | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|