| Date |
Text |
| 2019-04-12 10:31:34 | 1) SHT. A-1.0 - THE DOOR FOR TOILET ROOMS #108 & #109 |
| | CANNOT SWING INTO THE CLEAR FLOOR SPACE FOR THE |
| | LAVATORY OR THE WATER CLOSET. 2017 FBC-ACCESS. SEC. |
| | 603.2.3. |
| | 2) DRINKING FOUNTAINS ARE REQUIRED IN THIS SPACE PER |
| | 2017 FBC-PLUMBING TABLE 403.1 & 410.3. SHOW THE |
| | LOCATION OF THE REQUIRED DRINKING FOUNTAINS ON THE |
| | ARCHITECTURAL FLOOR PLAN AND ALSO ON THE PLUMBING PLANS |
| | AND WATER AND SANITARY RISERS. 2017 FBC-PLUMBING TABLE |
| | 403.1 & WPB AMEND. TO FBC 107.2.1. |
| | 3) A SERVICE SINK IS REQUIRED IN THIS SPACE PER 2017 |
| | FBC-PLUMBING TABLE 403.1. SHOW THE LOCATION OF THE |
| | SERVICE SINK ON THE ARCHITECTURAL FLOOR PLAN AND |
| | PLUMBING PLAN AND SANITARY AND WATER RISERS. |
| | 4) A LINT INTERCEPTOR IS REQUIRED FOR THE WASHING |
| | MACHINE PER 2017 FBC-PLUMBING SEC.1003.6. |
| | 5) SHT. A-4.0 - DETAIL #3 - ELEVATION - "A" - THE |
| | TOILET PAPER DISPENSER SHALL BE LOCATED A MINIMUM OF 7 |
| | INCHES AND A MAXIMUM OF 9 INCHES TO THE CENTER OF THE |
| | DISPENSER FROM THE FRONT OF THE TOILET BOWL.2017 |
| | FBC-ACCES. SEC.604.7. |
| | 6) SHT. P-0 - THE WASHING MACHINE SHALL BE INSTALLED ON |
| | A MINIMUM 3 INCH STACK. SHOW THIS ON THE PLAN. 2017 |
| | FBC-PLUMBING SEC.406.2. |
| | 7) THE WATER SUPPLY VALVES AT THE WASHING MACHINE BOX |
| | SHALL BE ACCESSIBLE PER FBC-PLUMBING SEC.606.3. |
| | 8) TEMPERED WATER IS REQUIRED AT THE LAVATORIES PER |
| | FBC-PLUMBING SEC.416.5. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |
| | |
| | |
| | |