2019-03-13 11:30:01BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 ADDRESS PLUMBING COMMENTS:
  
 1) THE REMOVAL OF THE EXISTING TUB AND CONVERTING IT TO
 A SHOWER IS NOT PERMITTED UNDER F.A.C WITH OUT A
 COMPLETE PLAN BEING PROVIDE SHOWING ALL USABLE BATHROOM
 AND KNOWING WHAT DESIGN SPEC WAS USED. FOR SHOWERS
 UNDER F.A.C YOU MUST SHOW AND HAVE A 48" X 30" PARALLEI
 APPROACH TO THE SHOWER WHICH THE TOILET IS NOT
 PERMITTED TO ENCROACH INTO. THE TOILET MUST KEEP THE
 18" CLEARANCE FROM THE TUB/SHOWER. I WOULD ADVISED
 CONSULTING A DESIGN PROFESSIONAL WITH FAIR HOUSING
 KNOWLEDGE.
  
 2) PLANS ARE NOT PERMITTED TO BE DRAWN IN PENCIL. PLANS
 MUST BE ON SUITABLE MATERIAL. FBC 107.2.1
  
 3) PROVIDE A PLAN SHOWING THE REQUIRED F.A.C CLEAR
 FLOOR SPACES WILL REMAIN. FBC 107.3.5
  
 ALSO:
  
 1) PROVIDE A PLAN SHOWING COMPLIANCE WITH FBC1210.2.3
 SHOWERS. AND FBC 1210.2.2 GRAB BARS
  
 SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH
 INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH,
 NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72
 INCHES (1829 MM) ABOVE THE DRAIN INLET.
  
 ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER
 DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN
 WALLS, SHALL BE INSTALLED AND SEALED TO PROTECT
 STRUCTURAL ELEMENTS FROM MOISTURE.
  
  
  
  