| 2019-03-08 13:57:55 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | JOSEAN A. DUPREY E.I., BN, PX |
| | BUILDING PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6716 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE |
| | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE |
| | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, |
| | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF |
| | WPB CHAPTER 109.3 |
| | |
| | 2. . PROVIDE FLOOR PLAN SHOWING LOCATION OF DOORS WITH |
| | DIMENSIONS OF ROUGH OPENINGS. IF NO CHANGES ARE TO BE |
| | MADE TO THE ROUGH OPENINGS, PROVIDE STATEMENT THAT |
| | WINDOWS WILL BE LIKE FOR LIKE. IF OPENINGS ARE ALTERED, |
| | PROVIDE FRAMING PLAN PER FBCR CHPT. 6 |
| | |
| | 3. PROVIDE GARAGE DOOR PRODUCT APPROVAL. FBC107 |
| | |
| | 4. THE PRODUCT APPROVAL NO. 17-1212.06 IS FOR A |
| | NON-IMPACT SLIDIGN GLASS DOOR. PLEASE INDICATE IF THERE |
| | IS EXISTING SHUTTERS FOR THIS OPENING. |
| | R301.2.1.2 PROTECTION OF OPENINGS. GLAZED OPENINGS IN |
| | BUILDINGS LOCATED IN WINDBORNE DEBRIS REGIONS SHALL BE |
| | PROTECTED FROM WINDBORNE DEBRIS. GLAZED OPENING |
| | PROTECTION FOR WINDBORNE DEBRIS SHALL MEET THE |
| | REQUIREMENTS OF THE LARGE MISSILE TEST OF ASTM E 1996 |
| | AND ASTM E 1886 REFERENCED THEREIN, SSTD 12, TAS 201, |
| | 202 AND 203 OR AAMA 506, AS APPLICABLE. THE APPLICABLE |
| | WIND ZONES FOR ESTABLISHING MISILE TYPES IN ASTM E 1996 |
| | ARE SHOWN IN SECTION R301.2.1.2.1. GARAGE DOOR GLAZED |
| | OPENING PROTECTION FOR WINDBORNE DEBRIS SHALL MEET THE |
| | REQUIREMENTS OF AN APPROVED IMPACT-RESISTING STANDARD |
| | OR ANSI/DASMA 115 |
| | FBC 107 |
| | |
| | |