| Date |
Text |
| 2019-03-12 08:55:40 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19021354 |
| | ADD: 831 VILLAGE BLVD. SUITE: 307 |
| | CONT: SIZ CONSTRUCTION CORP. |
| | TEL: 305-303-8111 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. MARCH 12/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) THE SUBMITTED PLANS ARE NOT SIGNED AND SEALED BY A |
| | DESIGN PROFESSIONAL. UNDER THE PROJECT DIRECTORY IT |
| | STATES: |
| | ARCHITECT: |
| | ARCHIDEZIGNS, LLC / LICENSE FOR ARCHITECT BUSINESS |
| | AA26002029 |
| | 1585 NE 26TH ST. |
| | WILTON MANORS, FL 33305 |
| | 954-934-9076 |
| | ARCHITECTS: FLORIDA ADMINISTRATIVE CODE 61G1-16.005. |
| | PROCEDURES FOR DIGITALLY SIGNING AND SEALING AND FOR |
| | ELECTRONICALLY TRANSMITTING PLANS, SPECIFICATIONS, |
| | REPORTS OR OTHER DOCUMENTS. |
| | |
| | MEP ENGINEERS |
| | B & K ENGINEERING GROUP CERTIFICATE OF AUTHORIZATION |
| | 31989 |
| | 11731 NW 39TH PLACE |
| | SUNRISE, FL 33323 |
| | 561-716-7120 |
| | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A |
| | SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE |
| | OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON |
| | ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | 2) THE JOBSITE VALUE OF THIS PROJECT IS $93,000.00 |
| | DOLLARS IN VALUE. PLEASE REVIEW WHERE UP TO $18,600.00 |
| | DOLLARS IN VALUE (0.20% X $93,000.00= $18,600.00) WILL |
| | BE SPENT ON ACCESSIBLE UPGRADES OVER AND BEYOND THE |
| | COST OF THE JOB TO MAKE THIS TENANT SPACE FULLY |
| | ACCESSIBLE. PLEASE REVIEW IN ORDER OF HOW THE FUNDS ARE |
| | TO BE SPENT. 2017 FBC-ACCESS. CODE SECTION: |
| | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED |
| | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL |
| | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE |
| | ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY |
| | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS |
| | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN |
| | ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS |
| | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS |
| | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, |
| | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET |
| | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING |
| | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE |
| | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION |
| | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) |
| | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE |
| | DRINKING FOUNTAIN. |
| | EITHER THE DESIGN PROFESSIONAL OR THE CONTRACTOR CAN |
| | CREATE ON THEIR LETTERHEAD A LETTER IN THE ORDER OF |
| | ALTERED AREAS HOW THE FUNDS WILL BE SPENT TO MAKE THIS |
| | PROJECT CODE COMPLIANT AS MUCH AS POSSIBLE WITHOUT |
| | GOING OVER THE DISPROPORTIONATE COST OF $18,600.00 IN |
| | VALUE FOR ACCESSIBILITY. |
| | |
| | 3) SHEET 005-A-141 IS SHOWN AS THE LIFE SAFETY SHEET. |
| | |
| | 3A) CAPACITY OF EXITS. THE PLAN STATES THE MINIMUM |
| | REQUIRED DOOR WIDTH IS 32 INCHES. PLEASE REVIEW THE |
| | 2017 FBC-B: |
| | 1010.1.1 SIZE OF DOORS. THE REQUIRED CAPACITY OF EACH |
| | DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD |
| | THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 |
| | INCHES. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS |
| | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE |
| | STOP, WITH THE DOOR OPEN 90 DEGREES). |
| | 2017 FBC-ACCESSIBILITY CODE 404.2.3 CLEAR WIDTH. DOOR |
| | OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES |
| | MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS |
| | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE |
| | STOP, WITH THE DOOR OPEN 90 DEGREES. |
| | |
| | 3B) THE LIFE SAFETY SHEET SHOWS 2 EXISTING RESTROOMS, |
| | BOTH SHOW A CIRCLE WITHIN BOTH, NOT DIMENSIONED, ON |
| | SHEET 002-A-101 THE DIMENSION PLAN DOES NOT SHOW |
| | DIMENSIONS TO THE EXISTING RESTROOMS. COMPLIANCE WITH |
| | THE 2017 FBC-ACCESSIBILITY CODE 213.2 NOR 603 CANNOT BE |
| | DETERMINED. |
| | |
| | 3C) THIS SHEET SHOWS CUSTOMER SEATING AND TABLES BUT |
| | DOES NOT GIVE THE HEIGHT OF THE ACCESSIBLE TABLE? SHOW |
| | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION |
| | 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK |
| | SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 4A) SHEET 010-A-401 DETAIL 1 SHOWS ONE OF THE EXISTING |
| | RESTROOMS AND STATES FOR REFERENCE ONLY. THIS DETAIL |
| | DOES NOT INDICATE THAT THIS IS SUPPOSED TO BE AN |
| | ACCESSIBLE RESTROOM ALTHOUGH THERE IS A CIRCLE WITHIN |
| | THE RESTROOM POSSIBLY REPRESENTING 5 FOOT DIAMETER AND |
| | COMPLIANCE WITH ACCESS. CODE 304.3.1 THE CIRCLE NOR |
| | DOES THE ROOM SHOW ANY DIMENSIONS INDICATING CODE |
| | COMPLIANCE. |
| | |
| | 4B) WITHIN THIS SAME RESTROOM THE PLAN DOES SHOW THE |
| | CLEAR FLOOR SPACE REQUIRED BY 604.3.1 BUT DOES NOT MEET |
| | THE OVERLAP REQUIREMENTS OF 604.3.2 OF THE ACCESS. |
| | CODE. |
| | |
| | 4C) PLEASE SEE THE ELEVATIONS FOR THE GRAB BARS, DETAIL |
| | 4 ELEVATIONS, THE GRAB BARS ARE DIMENSIONED FROM THE |
| | CENTERLINE OF THE GARB BAR, UNDER THE 2017 |
| | FBC-ACCESSIBILITY CODE YOU WOULD MEASURE FROM THE TOP |
| | OF THE BAR. |
| | |
| | 2017 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF |
| | GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL |
| | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE |
| | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING |
| | SURFACE, NOT CENTERLINE. |
| | |
| | 4D) IN THE ELEVATION 4 DETAIL 1 ELEVATION THE BACK GRAB |
| | BAR WOULD APPEAR NOT TO MEET THE REQUIREMENTS OF |
| | 604.5.2ACCESS. CODE FOR THE REAR WALL, COMPLIANCE |
| | CANNOT BE DETERMINED SINCE THERE ARE NO DIMENSIONS. |
| | |
| | 5) SHEET 011-A-402: THE LOCATION OF GRAB BARS AGAIN IS |
| | TAKEN FROM THE CENTERLINE NOT THE TOP OF THE GRIPPING |
| | SURFACE. 2017 FBC-ACCESSIBILITY CODE SECTION 609.4 |
| | POSITION OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN |
| | A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| | THE GRIPPING SURFACE, NOT CENTERLINE. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |