| Date |
Text |
| 2019-03-04 16:31:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | |
| | 1) SHEET A101- THERE IS AN AREA INDICATED AS MAN TRAP |
| | AREA. |
| | |
| | PLEASE PROVIDE A NARRATIVE OF WHAT THIS AREA IS FOR AND |
| | HOW WILL IT COMPLY WITH THE FLORIDA FIRE PREVENTION |
| | CODE, NFPA 101 CH 7, MEANS OF EGRESS. |
| | |
| | |
| | |
| | 2) SHEET A 501 - THERE ARE INDICATIONS OF ACCESS |
| | CONTROL AND DOOR RELEASE BUTTON. |
| | |
| | ALL ACCESS CONTROL INSTALLTIONS SHALL BE UNDER SEPARATE |
| | SHOP DRAWINGS AND PERMIT. |
| | |
| | ALL ACCESS CONTROL SHALL COMPLY WITH NFPA 101, CH 7 |
| | MEANS OF EGRESS. |
| | |
| | PLEASE REVIEW AND COMPLY AND PROVIDE AN APPLICABLE NOTE |
| | OF ACKNOWLEDGEMENT. |
| | |
| | |
| | |
| | 3) SHEET A 101 & A 201 - THERE IS AN INDICATION THAT |
| | DOOR 07 IS WITHIN A FIRE WALL, HOWEVER, THE DOOR |
| | SCHEDULE FOR DOOR 07 HAS NO RATING. |
| | |
| | THE WALL THE DOOR IS IN IS A 1 HOUR FIRE WALL AND THE |
| | DOOR SHOULD HAVE THE SAME RATING. |
| | |
| | |
| | PLEASE AND CORRECT. |
| | |
| | |
| | |
| | |
| | 4) SHEET A 201 - THERE IS AN INDICATION OF TWO DEAD |
| | BOLTS ON THE VAULT DOOR AND SELF LOCKING. |
| | |
| | NFPA 101 CH 7, MEANS OF EGRESS |
| | |
| | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE |
| | OF A KEY, A |
| | TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM |
| | THE EGRESS |
| | SIDE. |
| | |
| | PLEASE REVIEW AND PROVIDE HOW THESE LOCKAS WILL COMPLY. |
| | |
| | |
| | |
| | |
| | 5) SHEET A 101 & A 201 - THERE IS AN INDICATION THAT |
| | DOOR 09 IS WITHIN A FIRE WALL, HOWEVER, THE DOOR |
| | SCHEDULE FOR DOOR 09 HAS NO RATING. |
| | |
| | THE WALL THE DOOR IS IN IS A 1 HOUR FIRE WALL AND THE |
| | DOOR SHOULD HAVE THE SAME RATING. |
| | |
| | |
| | PLEASE AND CORRECT. |
| | |
| | |
| | |
| | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | |
| | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |