2019-03-11 09:31:16BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE WINDOWS PRODUCT APPROVALS SUBMITTED ARE FOR
 NON-IMPACT WINDOWS. THE WINDOWS INSTALLED MUST BE
 IMPACT OR SHUTTERS MUST BE INSTALLED.
 SHOW COMPLIANCE WITH FBC ? R301.2.1.2 PROTECTION OF
 OPENINGS. GLAZED OPENINGS IN BUILDINGS LOCATED IN
 WINDBORNE DEBRIS REGIONS SHALL BE PROTECTED FROM
 WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR
 WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE
 LARGE MISSILE TEST OF ASTM E 1996 AND ASTM E 1886
 REFERENCED THEREIN, SSTD 12, TAS 201, 202 AND 203 OR
 AAMA 506, AS APPLICABLE.
  
 2. IF SHUTTERS WERE INSTALLED PLEASE PROVIDE THE
 FOLLOWING:
 FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION OF
 OPENING PROTECTIVE DEVICES" OR PROVIDE ALL INFORMATION
 REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 3. PROVIDE ALL PRODUCT APPROVALS FOR SHUTTERS, WINDOWS
 AND DOORS INSTALLED. FBC 107
  
 4. PROVIDE ROUGH OPENING DIMENSIONS FOR WINDOWS AND
 DOOR OPENINGS. FBC 107
  
  