| Date |
Text |
| 2019-02-22 11:01:57 | PERMIT 19020752 - HIBISCUS & GARDENIA FIBER |
| | |
| | PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| | DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| | OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| | COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| | THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| | REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| | HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| | THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| | NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| | APPROVED. |
| | |
| | 1) COMMUNICATIONS FACILITIES PLACEMENT PERMIT |
| | APPLICATION CITY RIGHTS-OF-WAY - THE APPLICATION LISTS |
| | COLLOCATION ON EXISTING TOWER AS THE TYPE OF FACILITY; |
| | HOWEVER, THE DETAILS OF THE ANTENNA INSTALLATIONS WERE |
| | NOT PROVIDED. PLEASE PROVIDE A BRIEF NARRATIVE OF WHAT |
| | IS PROPOSED SO THAT STAFF CAN VERIFY THE TYPE OF |
| | FACILITY THAT YOU WILL BE INSTALLING. |
| | |
| | 2) ENGINEERING PLANS - THE ENGINEERING PLANS WERE |
| | SUBMITTED AT A 1 INCH = 50 FEET SCALE, WHICH DOES NOT |
| | COMPLY WITH THE CITY CODE SCALE REQUIREMENT OF 10FT, |
| | 20FT, OR 40FT SCALE. PROVIDE THE PLANS AT THE REQUIRED |
| | SCALE. |
| | |
| | 3) SURVEY OF UNDERGROUND FACILITIES - NO SURVEY WAS |
| | PROVIDED. |
| | |
| | A. PROVIDE A SURVEY SHOWING THE PROPERTY LINES, FOOTERS |
| | FOR ANY ABOVEGROUND FACILITIES, AND ANY TREES WITHIN |
| | THE RIGHT-OF-WAY ALONG THE FIBER CONDUIT PATH. |
| | |
| | B. THE ENGINEERING PLANS MUST SHOW THE SAME CONDITIONS |
| | AS THE SURVEY, SO THAT STAFF CAN VERIFY THAT NONE OF |
| | THE PROPOSED WORK (MARKER POLES, HANDHOLDS OR CONDUIT |
| | IS BEING INSTALLED ON PRIVATE PROPERTY AND THAT NO |
| | TREES (SPECIFICALLY THEIR ROOT SYSTEM) OR OTHER |
| | LANDSCAPED AREAS ARE BEING AFFECTED. |
| | |
| | 4) INVENTORY OF REGISTRANT'S EXISTING FACILITIES - NO |
| | INFORMATION ON EXISTING FACILITIES WAS PROVIDED. SHOW |
| | THIS INFORMATION ON THE PLANS AND PROVIDE A NARRATIVE. |
| | |
| | 5) CONCEALMENT METHODS DESCRIPTIONS - NO INFORMATION ON |
| | WHERE THE MARKER POLES WILL BE LOCATED AND TO HOW THEY |
| | WILL BE CONCEALED WAS PROVIDED. SHOW THIS INFORMATION |
| | ON THE PLANS AND PROVIDE A NARRATIVE. |
| | |
| | 6) ESTIMATED SCHEDULE - NO SCHEDULE WAS PROVIDED. |
| | PROVIDE A NARRATIVE OF THE ESTIMATED SCHEDULE OF THE |
| | PROPOSED WORK. |
| | |
| | 7) CITY UTILITY POLE USE - NO INFORMATION WAS PROVIDED |
| | IT THE FIBER IS FOR NEW POLES OR THE USE OF EXISTING |
| | UTILITY POLES. PROVIDE A NARRATIVE ON WHERE THE |
| | WIRELESS FACILITIES WILL BE LOCATED. |
| | |
| | 8) RESTORATION ESTIMATE - THE TOTAL CONSTRUCTION COST |
| | SHEET DOES NOT PROVIDE FOR THE RESTORATION ESTIMATE FOR |
| | THE SPECIFIC LOCATION AND THE EXACT SCOPE OF |
| | RESTORATION TO BE DONE. PROVIDE A CORRECT RESTORATION |
| | ESTIMATE. |
| | |
| | 9) EVIDENCE OF INSURANCE COVERAGE - THE CERTIFICATE OF |
| | LIABILITY INSURANCE NEEDS TO BE REVISED TO NAME THE |
| | CITY OF WEST PALM BEACH, ITS COMMISSIONERS, OFFICERS, |
| | EMPLOYEES AND AGENTS AS ADDITIONAL INSURED. |
| | |
| | 10) ELECTRONIC FORMAT OF SUBMITTAL - ONLY THE PLANS |
| | WERE PROVIDED ON THE DISC. A COPY OF ALL OF THE |
| | SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC |
| | FORMAT. |
| | |
| | 11) FEES PAID - NO FEES WERE SUBMITTED. PLEASE PROVIDE |
| | THE JUSTIFICATION AS TO WHY YOU SHOULD NOT PAY FEES. |
| | PLEASE SEE SECTION A ON PAGE 4 OF THE APPLICATION FOR |
| | THE EXEMPTIONS. IF YOU DO NOT MEET THE EXEMPTION, THE |
| | REQUIRED FEES MUST BE SUBMITTED. |
| | |
| | 12) AFFIDAVIT OF PROPERTY OWNER'S LIST - THE AFFIDAVIT |
| | WAS PROVIDED, BUT NO OWNERS LIST PROVIDED. PLEASE |
| | CLARIFY AND PROVIDE THE INFORMATION. |
| | |
| | 13) PUBLIC NOTICE MAILER AFFIDAVIT - THE AFFIDAVIT WAS |
| | PROVIDED, BUT NOTHING TO SHOW WHAT WAS MAILED OUT WAS |
| | PROVIDED. PLEASE CLARIFY AND PROVIDE THE INFORMATION. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |