| Plan Review Notes For Permit 19020686 |
| Permit Number |
19020686 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-07-30 16:27:27 | PLUMBING COMMENTS: APPROVED WITH PROVISO | | | 1.NEW GARAGE PLAN SHEET GS-1: PLUMBING RISER DIAGRAM IS | | | CODE COMPLIANT. | | | 2. NEW HOUSE PLAN SHEET P-1 COMMENTS NOTED ARE REDLINED | | | ON THE PLAN AND NO ACTION IS EREQUIRED. | | | A.SANITARY RISER DIAGRAM | | | B.CLOTHES WASHER AND SINK SHALL CONNECT TO BUILDING | | | DRAIN DOWNSTREAM OF THE BATHROOM FIXTURES TO COMPLY | | | WITH FBC RES P3108.1 | | | C.CONNECT FIXTURE DRAIN OF SINK TO VERTICAL WASTE PIPE | | | AT A POINT ABOVE THAT OF THE CLOTHES WASHER AND COMPLY | | | WITH FBC RES 3107.3. | | | E.ELIMINATE LOOP VENT AT HIS BATH AND COMPLY W/ FBC RES | | | P3108.1. | | | F.IN HER BATH, CONNECT TUB WASTE AND SHOWER WASTE | | | INDEPENDENTLY TO WET VENT AND SIZE WET VENT BETWEEN | | | SHOWER AND WATER CLOSET DRAIN 3? TO COMPLY WITH FBC RES | | | P3108.1. | | | G.RECONCILE FLOOR PLAN PIPING LAYOUT WITH SANITARY | | | RISER. | | | | | | A SEPARATE GAS PERMIT AND PLANS ARE REQUIRED | | | |
|