2020-08-06 15:26:56PERMIT 19020390 - WEST PALM BEACH NODE 2 SITE #15034001
 INTERSECTION S. FLAGLER DRIVE AND DATURA ST. - 3RD
 REVIEW
  
 FAILED
  
 THE CITY HAS REVIEWED THE PROPOSED POLE LOCATION AND
 HAS THE FOLLOWING COMMENTS:
  
 1) THE SURVEY PROVIDED WITH THE APPLICATION FAILS TO
 SHOW THE RIGHT-OF-WAY LINE. THE ENGINEERING PLAN BASED
 ON THE SURVEY SHOWS THE PROPERTY LINE AT THE BACK OF
 THE SIDEWALK; HOWEVER, THIS IS NOT ACCURATE. THE
 RIGHT-OF-WAY LINE IS CLOSER TO THE CURB. THIS LOCATION
 IS VERIFIED BY THE SURVEYS PROVIDED BY MCIMETRO FOR THE
 FIBER BORES ON VERIZON'S BEHALF. PLEASE NOTE THAT THE
 MCIMETRO PROVIDED SURVEYS WERE NOT SPECIFICALLY DONE TO
 VERIFY THAT THE PROPOSED POLE LOCATION IS INDEED WITHIN
 THE RIGHT-OF-WAY, SO IT IS NOT CONCLUSIVE. IN THE
 ABSENCE OF YOUR TEAM PROVIDING A SURVEY, WHICH CLEARLY
 SHOWS THE POLE LOCATION WITHIN THE RIGHT-OF-WAY, THIS
 LOCATION WILL NOT BE APPROVED. YOU MUST PROVIDE A
 SURVEY SHOWING THE ACCURATE LOCATION OF THE
 RIGHT-OF-WAY, THE CURB, THE TREE WILL AND OTHER
 FEATURES.
  
 2) THE ENGINEERING PLAN AND THE SURVEY SHOW THE
 PROPOSED POLE LOCATE ADJACENT TO AN EXISTING TREE WELL
 WHICH NOW ONLY CONTAINS THE PALM TREE STUMP. THE CITY
 HAS DETERMINED THAT THE INSTALLATION OF THE POLE WITHIN
 THE CENTER, INSTEAD OF ADJACENT TO, IS THE APPROPRIATE
 LOCATION FOR THE NEW POLE. IT WOULD BE IN LINE WITH THE
 EXISTING PALM TREES ON DATURA STREET AND NOT CREATE AN
 ADDITIONAL OBSTRUCTION OF THE SIDEWALK. THIS OF COURSE
 IS SUBJECT TO THE TREE WELL BEING SHOWN WITHIN THE
 RIGHT-OF-WAY BY YOUR UPDATED SURVEY. ANY PULL BOXES,
 HANDHOLES, ETC. WOULD ALSO NEED TO BE CLEARLY SHOWN
 WITHIN THE RIGHT-OF-WAY. YOU MUST PROVIDE AN UPDATED
 ENGINEERING PLAN SHOWING THE POLE IN THE TREE WELL.
  
 3) SINCE NEITHER THE SURVEY NOR THE ENGINEERING PLAN
 SHOW UTILITY LINES ADJACENT TO THE TREE WELL, YOU DO
 NOT NEED TO PROVIDE UTILITY PROVIDER LETTERS FOR THIS
 LOCATION.
  
 4) AS PART OF THE INSTALLATION WITHIN THE TREE WELL,
 YOU WILL BE REQUIRED TO EXCAVATE THE ROOT BALL AND ANY
 MATERIAL WITHIN THE TREE WELL AND INSTALL PAVERS TO
 MATCH THE EXISTING PAVERS TO FILL IN THE AREA BETWEEN
 THE PROPOSED POLE BASE AND THE EXISTING PAVERS. AS PART
 OF THE EVENTUAL RIGHT-OF-WAY PERMIT YOU WILL NEED TO
 HAVE A RESTORATION PLAN THAT INCLUDES THE INSTALLATION
 OF THE PAVERS
  
 OTHER THAN THE COMMENTS LISTED ABOVE, STAFF IS READY TO
 APPROVE YOUR WIRELESS COMMUNICATION FACILITY PERMIT.
  