2021-07-01 09:26:46REF #20121293
  
 CONTACT: [email protected]
2021-06-07 14:31:181. SH C1 PROVIDE LAT - LONG FOR FIBER/POWER PULL-BOX.
  
 CONTACT: [email protected]
2019-02-21 13:18:27PERMIT 19020384 - 370 S ROSEMARY AVE STREET POLE
  
 PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE
 DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401
 OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE
 COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION.
 THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO
 REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF
 HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS,
 THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION,
 NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE
 APPROVED.
  
 1) ENGINEERING PLANS / NO CD OF PLANS PROVIDED.
  
 A. THE ENGINEERING PLANS WERE SUBMITTED AT A 1/16TH = 1
 FOOT SCALE, WHICH DOES NOT COMPLY WITH THE CITY CODE
 SCALE REQUIREMENT OF 10FT, 20FT, OR 40FT SCALE. PROVIDE
 THE PLANS AT THE REQUIRED SCALE.
  
 B. 300 BLOCK OF S ROSEMARY AVE WAS RECONSTRUCTED LAST
 YEAR. THE ENGINEERING PLANS THAT YOU SUBMITTED DO NOT
 SHOW THE POST CONSTRUCTION CONDITIONS AND INCLUDING
 UNDERGROUND UTILITY WORK AS WELL AS THE USE OF A
 SUSPENDED PAVEMENT SYSTEM TO PERMIT AND EXPANDED TREE
 ROOT GROWTH. ALL UNDERGROUND UTILITIES AND FEATURES,
 SUCH AS THE SUSPENDED PAVEMENT SYSTEM, NEED TO BE
 PROVIDED ON THE SURVEY THUS DO NOT ACCURATELY SHOW THE
 PLACEMENT LOCATION FOR THE PROPOSED FACILITIES. PROVIDE
 ACCURATE PLANS BASED ON THE BELOW AND ABOVEGROUND
 SURVEYS.
  
 C) PROPOSED POLE DOES NOT SHOW ORIENTATION TO THE
 STREET.
  
 D) NO DIMENSIONS SHOWN ON SH C4.
  
 E) SH E4 / GROUND ROD DETAIL DIMENSION "A" NOT SHOWN.
  
 F) HAND HOLD NOT LOCATED ON DRAWING.
  
 G) ALL RESTORATION PER CITY OF WPB STANDARD DETAILS.
  
 H) ALL ROADWAY CUTS MIN OF 25FT EITHER SIDE OF TRENCH,
 FULL LANE.
  
 H) IRRIGATION LINES NOT SHOWN ON DRAWINGS.
  
 2) SURVEY OF UNDERGROUND FACILITIES - THE BASE OF THE
 POLE IS BEING INSTALLED UNDERGROUND SO THIS IS
 REQUIRED. SURVEY OVER AERIAL.
  
 A. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS
 SURVEY INFORMATION.
  
 3) SURVEY OF ABOVEGROUND FACILITIES - A NEW POLE IS
 BEING INSTALLED ABOVEGROUND SO THIS IS REQUIRED.
  
 A. AS PREVIOUSLY STATED, CLEMATIS STREET WAS JUST
 COMPLETELY RECONSTRUCTED. ALL ABOVEGROUND FEATURES,
 INCLUDING LANDSCAPE, NEED TO BE PROVIDED ON THE SURVEY.
  
 B. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS
 SURVEY INFORMATION.
  
 C. PLEASE NOTE THAT THE OUTDATED SURVEY DOES NOT
 PROVIDE THE SIZE OF THE EXISTING UTILITY POLE BASE
 DIAMETER, WHICH WILL NEED TO BE CORRECTED ON THE
 REVISED SURVEY.
  
 D. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN
 THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S
 EXISTING FACILITIES - NO INFORMATION ON EXISTING
 FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE
 PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO
 FACILITIES, THIS SHALL BE NOTED ON THE SURVEY.
  
 E. PLEASE NOTE: THE EXISTING DECORATIVE LIGHTS SHOWN ON
 THE SURVEY ARE 17 FEET TALL (CITY CODE REQUIREMENT FOR
 CLEMATIS STREET). THE SUPPORT POLE INCLUDED WITH THE
 APPLICATION IS 25 FEET IN HEIGHT, WHICH EXCEEDS THE
 ALLOWANCE LISTED IN SECTION 94-411(G)(1) OF THE CITY
 CODE.
  
 4) CONCEALMENT METHODS DESCRIPTIONS - NO CONCEALMENT
 INFORMATION WAS PROVIDED. PLEASE NOTE THAT THE PROPOSED
 SUPPORT POLE DOES NOT MEET THE CITY CONCEALMENT
 STANDARDS OUTLINED IN SECTION 78-411 OF THE CITY CODE.
 PROVIDE PLANS AND NARRATIVE ON HOW THE INSTALLATION
 COMPLIES WITH THE CITY'S CONCEALMENT REQUIREMENT.
  
 5) RESTORATION ESTIMATE - YOU MUST PROVIDE A
 RESTORATION ESTIMATE FOR THE SPECIFIC LOCATION OF THE
 POLE, NOT A GENERIC ESTIMATE THAT IS NOT LINKED TO THE
 SPECIFIC LOCATION AND WORK TO BE DONE.
  
 6) RADIO FREQUENCY INTERFERENCE - NO INFORMATION WAS
 PROVIDED THAT THE PROPOSED FACILITIES WILL NOT CAUSE
 RADIO FREQUENCY INTERFERENCE WITH THE CITY'S PUBLIC
 SAFETY COMMUNICATIONS EQUIPMENT. PROVIDE A STATEMENT
 REGARDING RADIO FREQUENCY INTERFERENCE.
  
 7) EVIDENCE OF INSURANCE COVERAGE - THE CERTIFICATE OF
 LIABILITY INSURANCE LISTS PALM BEACH COUNTY AS THE
 ADDITIONAL INSURED. THE CERTIFICATE OF LIABILITY
 INSURANCE NEEDS TO BE REVISED TO NAME THE CITY OF WEST
 PALM BEACH, ITS COMMISSIONERS, OFFICERS, EMPLOYEES AND
 AGENTS AS ADDITIONAL INSURED.
  
 8) START OF OPERATION - AN ATTESTATION FROM THE
 COMMUNICATIONS FACILITIES SERVICE PROVIDER THAT
 COMMUNICATIONS SERVICES FACILITIES WILL BE INSTALLED
 AND OPERATIONAL ON THE PROPOSED STRUCTURE NO LATER THAN
 NINE MONTHS AFTER THE DATE THE APPLICATION IS APPROVED
 IS REQUIRED. PROVIDE THE REQUIRED ATTESTATION.
  
 9) PUBLIC UTILITY LETTERS, TELEPHONE, NATURAL GAS,
 ELECTRIC SERVICE, AND TELEVISION CABLE - THE PUBLIC
 UTILITY LETTERS WERE NOT PROVIDED. WHILE IMPORTANT, THE
 811 RESPONSE FORM DOES NOT ADDRESS THIS COMMENT.
 PROVIDE COPIES OF THE PUBLIC UTILITY LETTERS.
  
 10) ELECTRONIC FORMAT OF SUBMITTAL - THE SUBMITTAL WAS
 NOT PROVIDED IN ELECTRONIC FORM. A COPY OF ALL OF THE
 SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC
 FORMAT.
  
 11) PROOF OF MAILING NOTICE TO OWNERS, ONE COPY OF
 ADDRESS LIST OF PROPERTY OWNER'S ADDRESSES WITHIN 250
 FEET AND ONE COPY OF RADIUS MAP PROVIDED BY THE PAPA
 SHOWING THOSE PROPERTIES WITHIN 250 FEET OF AFFECTED
 RIGHTS-OF-WAY - A COPY OF THE RADIUS MAP WAS NOT
 SUBMITTED. THE OWNER'S ADDRESS LIST, WHILE SUBMITTED IS
 SUCH A SMALL FONT THAT IT IS NOT EASILY READABLE.
 PLEASE PROVIDE THE RADIUS MAP FROM PAPA AND THE ADDRESS
 LIST AT A BIGGER, READABLE FONT.
  
 12) PUBLIC NOTICE MAILER AFFIDAVIT - THE AFFIDAVIT WAS
 PROVIDED, BUT NOTHING TO SHOW WHAT WAS MAILED OUT WAS
 PROVIDED. PLEASE CLARIFY AND PROVIDE THE INFORMATION.
  
 CONTACT GORDON PATRIE @ (561) 494-1082
 [email protected]
  