2019-02-11 15:26:42BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 TEMPORARY MEMBRANE STRUCTURES
 (TENTS) FBC CHPT. 31
  
 ADVISORY: THE BUILDING OFFICIAL HAS MANDATED THE
 FOLLOWING REQUIREMENTS FOR ALL TEMPORARY MEMBRANE
 STRUCTURES WITH A SPAN OF 30 FEET OR GREATER IN ANY
 DIRECTION:
  
 1. PROVIDE STRUCTURAL CONNECTOR DETAILS. INCLUDE
 BASEPLATE/TIEDOWN DETAIL.
 2. PROVIDE STRUCTURAL EVALUATION OF STRUCTURE.
  
 BOTH DOCUMENTS TO BE REVIEWED, SIGNED AND SEALED BY A
 DESIGN PROFESSIONAL.
  
 3103.1 CONFORMANCE. - COMPLY AS APPLICABLE
 1. PROVIDE STATEMENT FOR DATE OF ASSEMBLY AND DATE OF
 REMOVAL.
 2. PROVIDE SITE PLAN. SHOW LOCATION OF PROPOSED
 STRUCTURE AND DISTANCE TO PROPERTY LINES AND OTHER
 STRUCTURES PER FBC CHPT. 6, SEC. 602.
 3. CONFORMANCE REQUIREMENTS PER SEC. 3103.1.1
 TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE
 STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS,
 ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY
 REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC
 HEALTH, SAFETY AND GENERAL WELFARE.
 A. STRUCTURAL STRENGTH PER FBC CHPT. 16 ? SUPPLIER TO
 PROVIDE CERTIFIED REPORT.
 B. FIRE SAFETY ? PROVIDE FLAME SPREAD TEST REPORTS PER
 NFPA 701.
 C. MEANS OF EGRESS 1) OPEN SIDES ? NO LIFE SAFETY PLAN
 REQUIRED.
  2) CLOSED SIDES ? PROVIDE LIFE SAFETY PLAN
  A) STATE OCCUPANT LOAD.
  B) IDENTIFY MEANS OF EGRESS.
  C) IDENTIFY PATH OF TRAVEL ? 100 FT. OR LESS TO
 EXIT.
  D. ACCESSIBILITY 1) IDENTIFY ACCESSIBLE ROUTE ON SITE
 PLAN
  E. LIGHT 1) OPEN SIDES ? N/A
  2) CLOSED SIDES ? PER SEC. 1008.2.1 > 1 FOOT CANDLE
  F. VENTILATION 1) OPEN SIDES ? N/A
  2) CLOSED SIDES ? PER SEC. 1203
  G. SANITARY 1) IDENTIFY EXISTING PERMANENT FACILITIES
 ON SITE PLAN
  2) PROVIDE PORTABLE FACILITIES PER TABLE 2902.1
  
  
 APPLICANT WILL ENSURE AN ACCESSIBLE RESTROOM IS LOCATED
 NOT MORE THAN 500 FEET FROM TENT.
  