| Date |
Text |
| 2019-02-28 11:02:47 | MR. GOMEZ, |
| | PLEASE SEE THE BELOW COMMENTS AND PLEASE LET ME KNOW IF |
| | THEY WILL SUFFICE TO MOVE FORWARD WITH THIS PERMIT. |
| | THANK YOU FOR YOUR ASSISTANCE. |
| | KELLY |
| | |
| | GOOD AFTERNOON, |
| | BELOW PLEASE FIND THE COMMENTS |
| | |
| | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | ORIGINAL COMMENT: |
| | 1- ROOFING CONTRACTOR SUBMITTED FLORIDA PRODUCT |
| | APPROVAL FOR SKYLIGHTS. SCOPE OF WORK IS NOT CLEAR. |
| | ACCORDING TO CITY RECORDS, THIS HOUSE HAD NOT SKYLIGHTS |
| | AT TIME OF CONSTRUCTION AND THERE ARE NOT RECORDS FOR |
| | PERMIT APPLICATIONS FOR SKYLIGHT INSTALLATION. ALSO, |
| | PAPA AERIAL VIEW DOESN'T SHOW SKYLIGHTS EITHER. FRAMING |
| | AND INSTALLATION OF SKYLIGHTS CAN NOT BE DONE BY THE |
| | ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSES A |
| | LICENSE TO DO SO. SEE SEC. 489.113 F.S. NEED TO PROVIDE |
| | COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR THE NEW |
| | SKYLIGHT, INCLUDING LOCATION ON THE ROOF. AND, NEED |
| | SEPARATE PERMIT OR SUB-PERMIT APPLICATION FOR THIS |
| | ADDITIONAL SCOPE OF WORK. |
| | |
| | -WE WOULD LIKE TO WITHDRAWAL THE PRODUCT APPROVAL FOR |
| | THE SKYLIGHTS PLEASE. WE WILL NOT BE COMPLETING ANY |
| | SKYLIGHT WORK. *************** |
| | |
| | ORIGINAL COMMENT: |
| | 2- ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL |
| | FL10450-R10 SUBMITTED. CLEARLY SPECIFY IF THE |
| | UNDERLAYMENT IS GOING TO BE A DIRECT-DECK UNDERLAYMENT |
| | OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING |
| | IS REQUIRED: |
| | A) FOR DIRECT-BOND TO DECK SEE NOTE AT BOTTOM OF SEC. |
| | 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC. |
| | 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE |
| | WITH THE DESIGN PRESSURES OF SEC. R301.1 |
| | FBC-RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T |
| | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT |
| | CAN NOT BE USED. |
| | |
| | 5.6.1 UNDERLAYMENT IS GOING TO BE DIRECT-BOND TO DECK |
| | 5.6.4 |
| | #1 MAXIMUM DESIGN PRESSURE = -75.0 PSF: FIELD & |
| | PERIMETER ************************* |
| | #2 MAXIMUM DESIGN PRESSURE = -120.0 PSF: |
| | CORNER************************************ |
| | |
| | ROOFPRO |
| | 6555 GARDEN ROAD, SUITE 18 |
| | RIVIERA BEACH, FL 33404 |
| | 561-249-0247 |
| | |
| | WWW.ROOFPRO411.COM |
| | |
| | |
| | |