Plan Review Notes
Plan Review Notes For Permit 19020363
Permit Number 19020363
Review Stop M
Sequence Number 1
Notes
Date Text
2019-03-11 12:19:49MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CANNOT DETERMINE IF ADDITION ENCROACHES INTO THE
 SPECIAL FLOOD HAZARD AREA TRANSECTING THE PROPERTY.
 2. PROVIDE SURVEY AND SITE PLAN.
 3. IF ADDITION QUALIFIES STRUCTURE AS A SUBSTANTIAL
 IMPROVEMENT, ALL MECHANICAL EQUIPTMENT AND UTILITIES
 SHALL BE ELEVATED AT OR ABOVE THE DESIGN FLOOD
 ELEVATION.
  
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
  
 ADVISORY: RETURN AIR GRILLS SHOULD BE LOCATED ON
 OPPOSITE SIDE OF ROOM THAT SUPPLY AIR IS LOCATED.
  
  