| 2021-04-07 16:32:15 | DENIED |
| | |
| | PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN |
| | MCIMETRO PROJECT #1806CQB.1 3/25/21 RESUBMITTAL |
| | |
| | PROVIDE WRITTEN RESPONSE TO COMMENTS. |
| | |
| | THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT |
| | WILL NOT BE APPROVED. |
| | |
| | 1) ENGINEERING PLAN - REPEAT COMMENT: THE REVISED BORE |
| | LOCATION INCLUDES A CROSSING OF FERN STREET WHICH |
| | INCLUDES A PROPOSED OPEN CUT, THREE FEET DEEP, LEADING |
| | TO HANDHOLE 8+95. THE LOCATION OF THE PROPOSED OPEN CUT |
| | IS AN AREA THAT INCLUDES BIOSWALE PITS THAT ARE |
| | SURROUNDED BY STRUCTURAL SOIL. THE STRUCTURAL SOIL HAS |
| | EXACTING INSTALLATION STANDARDS AND MAY NOT BE |
| | DISTURBED. STAFF PROVIDED THE AS ENGINEERING DRAWINGS |
| | SHOWING A DETAIL FOR THE BIOSWALE PIT WITH THE |
| | SURROUNDING STRUCTURAL SOIL. THE FULL AREA COVERED BY |
| | THE STRUCTURAL SOIL UNDER THE SIDEWALK IS A MINIMUM OF |
| | 19 FEET EAST TO WEST AND THE FULL DEPTH OF THE SIDEWALK |
| | FROM THE CURB TO THE EDGE OF THE RIGHT-OF-WAY LINE. THE |
| | DETAILS ARE PROVIDED ON SHEET C1.10 OF THE DRAWINGS. |
| | |
| | IT APPEARS THAT YOU SHIFTED THE BIOSWALE PIT TO THE |
| | EAST OF HANDHOLE STA 8+95; HOWEVER, THE DIMENSION FROM |
| | THE LIMITS OF THE STRUCTURAL SOIL TO THE EDGE OF WHERE |
| | YOU WILL CUT THE SIDEWALK TO SET THE HANDHOLE WAS NOT |
| | PROVIDED. THIS DIMENSION MUST BE AT LEAST SEVEN (7) |
| | FEET TO AVOID DISTURBING THE STRUCTURAL SOIL AND |
| | CLEARLY SHOWN ON THE PLAN (A BLOW UP OF THE AREA OF |
| | WORK WOULD BE BEST). |
| | |
| | THE FIBER LEADING TO THE WEST SIDE OF STA 8+95 WAS NOT |
| | CHANGED AND CONTINUES TO SHOW AN OPEN CUT THROUGH THE |
| | STRUCTURAL SOIL BOTH TO THE WEST OF THE BIOSWALE PIT |
| | AND BETWEEN THE BIOSWALE PIT AND THE EDGE OF THE |
| | RIGHT-OF-WAY. STAFF WILL NOT SUPPORT THIS PROPOSAL AS |
| | IT WILL DAMAGE THE STRUCTURAL SOIL. |
| | |
| | AFTER THE SEVEN FOOT OFFSET FROM EACH OF THE BIOSWALE |
| | PITS TO AVOID THE STRUCTURAL SOIL, THERE WILL BE AN |
| | APPROXIMATELY 15 FOOT CLEAR AREA WHERE YOU CAN INSTALL |
| | THE HANDHOLE AND THE FUTURE SMALL CELL WIRELESS |
| | FACILITY POLE. YOU WILL NEED TO BORE DIRECTLY FROM THE |
| | HANDHOLE STA 8+00 TO HANDHOLE STA 8+95 UNDER FERN |
| | STREET. |
| | |
| | 2) THE SURVEY FOR THE INTERSECTION OF N CLEMATIS STREET |
| | AND FLAGLER DRIVE DOES NOT INCLUDE THE RIGHT-OF-WAY |
| | LINE, THE CURB LINE OR OTHER FEATURES. |
| | |
| | PLEASE NOTE: |
| | |
| | THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811 |
| | TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL |
| | DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST |
| | BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE |
| | WORK. |
| | |
| | THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A |
| | CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE |
| | WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES |
| | THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS, |
| | OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |