| Date |
Text |
| 2020-04-09 13:43:21 | PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN |
| | MCIMETRO PROJECT # 1806CQB.1 |
| | |
| | PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| | DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| | OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| | COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| | THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| | REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| | HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| | THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| | NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| | APPROVED. |
| | |
| | 1) SURVEY - THE SURVEY DOES NOT SHOW SUFFICIENT |
| | INFORMATION FOR STAFF TO VERIFY WHAT IS SHOWN ON THE |
| | ENGINEERING PLANS. . |
| | |
| | A. THE SURVEY MUST BE PROVIDED AT A LEGIBLE SCALE AND |
| | CLEARLY SHOW THE RIGHT-OF-WAY LINE AND THE SIDEWALK. |
| | |
| | B. ALL UNDERGROUND UTILITIES NEED TO BE PROVIDED ON THE |
| | SURVEY. IF THE BORE IS PROPOSED WITHIN FIVE (5) FEET OF |
| | AN EXISTING FPL FACILITY YOU NEED TO PROVIDE A LETTER |
| | FROM FPL THAT THE PROPOSED BORE DOES NOT INTERFERE WITH |
| | THE PROVISIONS OF THEIR SERVICES. THE PROVIDED FPL |
| | LETTER DID NOT ADDRESS THIS PORTION OF FLAGLER DRIVE OR |
| | FERN STREET. |
| | |
| | C. THE LOCATIONS OF THE TREES WITH THEIR ROOT ZONE AND |
| | UTILITY POLES WITH THEIR FOOTERS NEED TO BE SHOWN. THE |
| | FIBER BORE NEEDS TO BE CLEARLY SHOWN AVOIDING DAMAGE TO |
| | THE ROOT ZONES (THIS MAY OCCUR ON THE ENGINEERING |
| | PLAN). |
| | |
| | D. THE ENGINEERING PLANS MUST SHOW THE SAME CONDITIONS |
| | AS THE SURVEY, SO THAT STAFF CAN VERIFY THAT NONE OF |
| | THE PROPOSED WORK IS BEING INSTALLED ON PRIVATE |
| | PROPERTY. |
| | |
| | 2) EVIDENCE OF INSURANCE COVERAGE |
| | |
| | A. SINCE THE COMMUNICATIONS FACILITIES PLACEMENT PERMIT |
| | APPLICATION LISTS MCIMETRO ACCESS TRANSMISSION SERVICES |
| | CORP AS THE REGISTRANT, THIS IS WHOSE CERTIFICATE OF |
| | LIABILITY INSURANCE NEEDS TO BE PROVIDED. |
| | |
| | B. THE CERTIFICATE OF LIABILITY INSURANCE NEEDS TO BE |
| | REVISED TO NAME THE CITY OF WEST PALM BEACH, ITS |
| | COMMISSIONERS, OFFICERS, EMPLOYEES AND AGENTS AS |
| | ADDITIONAL INSURED. |
| | |
| | C. THE CERTIFICATE HOLDER IS THE ENGINEERING SERVICES |
| | DEPARTMENT. |
| | |
| | 3) POLE STYLE - PLEASE NOTE THAT THE FUTURE POLES ARE |
| | REQUIRED TO MEET THE CITY CONCEALMENT STANDARDS |
| | OUTLINED IN SECTION 78-411 OF THE CITY CODE. |
| | |
| | NOTE: STAFF WILL NOT APPROVE THE INSTALLATION OF A SIX |
| | (6) FOOT TALL MARKER POLE ADJACENT TO THE HANDHOLE. IF |
| | THE HANDHOLE NEED TO BE MARKED, THEN PROVIDE THE |
| | INFORMATION ON THE HANDHOLE COVER. |
| | |
| | 4) ELECTRONIC FORMAT OF SUBMITTAL - A COPY OF ALL OF |
| | THE SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC |
| | FORMAT. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |