| Date |
Text |
| 2019-03-19 16:23:31 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1ST REVIEW: DENIED |
| | PLUMBING COMMENTS |
| | 1. RE: A0.04 AMBULATORY STALL; FBC ACC 604.8.2.1 CALLS |
| | FOR STALL TO BE 35? TO 37? WIDE. WC TO BE 17?-19? FROM |
| | NEAR SIDE WALL TO CENTER PER FBC ACC 604.2. DETAIL |
| | SHOWS 17?-22?. PLEASE CLARIFY ON DETAIL NOTING THE |
| | WIDTH OF THE STALL AND THE CORRECT DISTANCE FROM NEAR |
| | SIDE WALL TO CENTER OF WC. |
| | 2. RE: TOILET COMPARTMENT CONFIGURATIONS SHOWN ON A4.21 |
| | DO NOT MATCH DETAIL 3/A0.04 AND NO TURNING RADIUS IS |
| | PROVIDED ON EITHER PLAN. PER WPB FBC 107.2.1, PLEASE |
| | CLARIFY. |
| | 3. RE: A4.21, PER WPB FBC 107.2.1, DESIGNATE ONE OF THE |
| | TWO URINALS AS THE ADA COMPLIANT URINAL AS REQUIRED BY |
| | FBC ACC 213.3.3 AND PROVIDE ON DETAIL 3/A0.04, THE |
| | ELEVATION SHOWING COMPLIANCE WITH FBC ACC 605.2. |
| | 4. RE: P0.1; PLATFORM MOUNTED WATER HEATER DETAIL. THE |
| | T&P LOOKS AS IF IT IS DISCHARGING TO THE PAN. A DRAIN |
| | FROM THE PAN IS IDENTIFIED AS THE T&P DISCHARGE. PLEASE |
| | CLARIFY PER WPB FBC 107.2.1 |
| | 5. UPON A REVIEW OF PAST PERMITS AT THIS ADDRESS, I CAN |
| | FIND NO RECORD OF AN INTERIOR STORM DRAINAGE SYSTEM. |
| | PLEASE CLARIFY. ARE THE DRAINS DESCRIBED ON P2.1, KEY |
| | NOTE #3 DRAINING HORIZONTALLY ABOVE THE ROOF AND |
| | DISCHARGING TO GUTTERS? IF SO, HOW ARE THEY BEING |
| | SUPPORTED.? PLEASE CLARIFY ON THE PLANS PER WPB FBC |
| | 107.2.1. |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |