2019-02-13 10:39:57RESIDENTIAL (R3)ADDITION BUILDING REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1-IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 1106
 FBC-EXISTING BUILDING AND SEC. R502 FBC-ENERGY
 CONSERVATION.
 NOTE: COORDINATE WITH PLANS TO AVOID CONFLICTS/DELAYS.
  
 3- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 FBC R 401.3 (DRAINAGE)
 FBC 107.2.5 (SITE PLAN)
 FBC 110.9 (IMPACT OF CONSTRUCTION)
  
 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A) METAL ROOF AS SPECIFIED ON PLANS.
  
 B) SELF-ADHERED ROOF UNDERLAYMENT TO BE USED FOR METAL
 ROOFING AS SPECIFIED ON PLANS.
  
 C) SLIDING GLASS DOORS.
  
 D) FRENCH DOORS.
  
 E) OVERHEAD GARAGE DOOR
  
 F) FIXED WINDOWS.
  
 G) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 H)PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
  
 6- STRUCTURAL BUCK DETAILS FOR DOORS AND WINDOWS ARE
 INCOMPLETE. DETAILS PROVIDED ARE MISSING THE FASTENER
 SPECIFICATIONS. SPECIFY FASTENER TYPE, SIZE AND
 SPACING. SEC. R301.1 FBC-RESIDENTIAL.
  
 7- ALL ARCHITECTURAL DRAWINGS NEED TO HAVE THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN AS
 REQUIRED BY SEC. 107.2.1 CITY AMENDMENTS.
  
 8- BRACKET DETAIL ON SHEET A202 IS MISSING THE
 FASTENERS SPECIFICATIONS. SPECIFY, TYPE AND SIZE. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 9- PROVIDE ICYNENE ICC EVALUATION REPORT TO SHOW
 COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. DESIGNER OR
 RECORD TO REVIEW AND APPROVE PRIOR TO SUBMITTAL.
  
 10- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE CEILING AT THE PATIO AREA AND ALL
 OTHER EXTERIOR SOFFITS. SEC. R301.1 FBC-RESIDENTIAL.
  
 11- PARAPET DETAILS ON SHEET A502: PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR THE ATTACHMENT OF THE
 2X10 BLOCKING AND THE ALUMINUM COPING. SEC. R301.1
 FBC-RESIDENTIAL.
  
 12- ENGINEER OF RECORD TO REVISE ROOF DESIGN
 INFORMATION ON SHEET S0.0: THE SKETCH DHOW DOESN'T
 REFLECT THE ROOFING CONFIGURATION ON THIS BUILDING.
 THIS IS A MONO SLOPE ROOF. REVISE DESIGN PRESSURES
 ACCORDINGLY. SEC. R301.1 FBC-RESIDENTIAL.
  
 13- ROOF PLAN ON SHEET A100 SPECIFIES 3'-0" OVERHANG,
 WHILE WALL SECTION S1 ON SHEET SD.2 SPECIFIES 2'-6"
 MAX. REVISE/CLARIFY AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 14- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  