| Plan Review Notes For Permit 19010315 |
| Permit Number |
19010315 |
|
| Review Stop |
M |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2019-08-22 09:44:25 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | 1- MASTER BEDROOM TRANSFER DUCT TO BE 9" MIN. SEC. | | | M1602.3 FBC-RESIDENTIAL. | | | 2- REVISE MASTER BEDROOM TRANSFER DUCT LOCATION OR | | | PROVIDE CALCULATIONS SHOWING HOW BEDROOM #2 WILL HANDLE | | | THE MASTER BEDROOM AND BEDROOM #2 RETURN AIR. SEC. | | | 107.2.1.2 CITY AMENDMENTS. | | | |
|