| 2019-06-27 07:51:48 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | ***ENERGY CALCULATIONS NEED TO BE CERTIFIED BY THE |
| | OWNER PRIOR TO APPROVE THE BUILDING REVIEW. |
| | |
| | |
| | |
| | 1- OK |
| | |
| | 2- OK |
| | |
| | ORIGINAL COMMENT: |
| | 3- PROVIDE ENERGY CALCULATIONS (2 COPIES). SEC. R101.5 |
| | FBC-ENERGY CONSERVATION. NOTE: CALCULATIONS SUBMITTED |
| | ARE FOR ANOTHER ADDRESS (THEREFORE, THEY WERE NOT |
| | REVIEWED) AND TOO OLD. NEW CALCULATIONS FOR CORRECT |
| | ADDRESS AND WITH CURRENT CODE (2017). |
| | |
| | RESPONSE: |
| | A)THE ENERGY FORM R405-2017 IS REQUIRED TO BE CERTIFIED |
| | AT THE BOTTOM BY THE OWNER OR THE OWNER LEGALLY |
| | DESIGNATED AGENT PRIOR TO RECEIVE THE PERMIT AS |
| | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, |
| | 6TH EDITION (2017). |
| | |
| | B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING HOUSE ADDRESS AND BUILDER NAME. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | C)REVISE ITEM #4 ON PAGE 1 OF 5. NUMBER OF BEDROOMS |
| | DOESN'T MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | D)REVISE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 5. |
| | MISSING WINDOWS ON THE SOUTH SIDE. THERE IS ONLY ONE |
| | WINDOW ON THE NORTH SIDE NOT 2. REVISE THE WINDOW |
| | OVERHANG DEPTH FOR WINDOW #7. SEE PLANS AND REVISE AS |
| | REQUIRED TO MATCH. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | E)TYPICALLY THE ATTIC VENT RATIO IS 1/150. PAGE 2 OF 5 |
| | SPECIFIES 1/300. PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS SHOWING COMPLIANCE WITH THE EXCEPTION OF |
| | SEC. R806.2 FBC-RESIDENTIAL WHEN SPECIFYING A VENT |
| | RATIO OF 1/300 AS SHOWN ON PAGE 2 OF 5. NOTE: |
| | COORDINATE WITH PLANS TO AVOID CONFLICTS/DELAYS. |
| | |
| | F) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL |
| | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| | CONSERVATION. |
| | |
| | NOTE: |
| | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND |
| | SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS |
| | ARE NOT USING THE DEFAULT FACTOR. |
| | |
| | 4- OK. |
| | |
| | 5- OK |
| | |
| | 6- A)OK |
| | |
| | B)OK. |
| | |
| | 7- OK |
| | |
| | 8-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL) |
| | |
| | A) OK. |
| | |
| | ORIGINAL COMMENT: |
| | B) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS |
| | SPECIFIED ON SHEET A5. |
| | |
| | RESPONSE: |
| | NO SUBMITTED. |
| | |
| | 9-DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE |
| | PRODUCT APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | 10- OK |
| | |
| | 11- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR |
| | REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW |
| | COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD |
| | DRAWINGS/DOCUMENTS FOR REFERENCE. |
| | |
| | 12- BEDROOM #2 EGRESS WINDOW SH34EH: PROVIDE |
| | MANUFACTURER'S CUT SHEETS TO VERIFY MIN. CLEAR |
| | OPENINGS. SEC. R310.2.1 FBC-RESIDENTIAL. |
| | |
| | |