2019-06-27 07:51:48NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***ENERGY CALCULATIONS NEED TO BE CERTIFIED BY THE
 OWNER PRIOR TO APPROVE THE BUILDING REVIEW.
  
  
  
 1- OK
  
 2- OK
  
 ORIGINAL COMMENT:
 3- PROVIDE ENERGY CALCULATIONS (2 COPIES). SEC. R101.5
 FBC-ENERGY CONSERVATION. NOTE: CALCULATIONS SUBMITTED
 ARE FOR ANOTHER ADDRESS (THEREFORE, THEY WERE NOT
 REVIEWED) AND TOO OLD. NEW CALCULATIONS FOR CORRECT
 ADDRESS AND WITH CURRENT CODE (2017).
  
 RESPONSE:
 A)THE ENERGY FORM R405-2017 IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM BY THE OWNER OR THE OWNER LEGALLY
 DESIGNATED AGENT PRIOR TO RECEIVE THE PERMIT AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017).
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING HOUSE ADDRESS AND BUILDER NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)REVISE ITEM #4 ON PAGE 1 OF 5. NUMBER OF BEDROOMS
 DOESN'T MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 D)REVISE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 5.
 MISSING WINDOWS ON THE SOUTH SIDE. THERE IS ONLY ONE
 WINDOW ON THE NORTH SIDE NOT 2. REVISE THE WINDOW
 OVERHANG DEPTH FOR WINDOW #7. SEE PLANS AND REVISE AS
 REQUIRED TO MATCH. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 E)TYPICALLY THE ATTIC VENT RATIO IS 1/150. PAGE 2 OF 5
 SPECIFIES 1/300. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING COMPLIANCE WITH THE EXCEPTION OF
 SEC. R806.2 FBC-RESIDENTIAL WHEN SPECIFYING A VENT
 RATIO OF 1/300 AS SHOWN ON PAGE 2 OF 5. NOTE:
 COORDINATE WITH PLANS TO AVOID CONFLICTS/DELAYS.
  
 F) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS
 ARE NOT USING THE DEFAULT FACTOR.
  
 4- OK.
  
 5- OK
  
 6- A)OK
  
 B)OK.
  
 7- OK
  
 8-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) OK.
  
 ORIGINAL COMMENT:
 B) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS
 SPECIFIED ON SHEET A5.
  
 RESPONSE:
 NO SUBMITTED.
  
 9-DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 10- OK
  
 11- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 12- BEDROOM #2 EGRESS WINDOW SH34EH: PROVIDE
 MANUFACTURER'S CUT SHEETS TO VERIFY MIN. CLEAR
 OPENINGS. SEC. R310.2.1 FBC-RESIDENTIAL.
  
  