| Plan Review Notes For Permit 19010315 |
| Permit Number |
19010315 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2019-01-24 15:44:47 | CODES IN EFFECT: | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 5TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RE: PLAN HEET A1; PLUMBING RISER. | | | A. CONNECT EACH WATER CLOSET AND SHOWER FIXTURE DRAIN | | | INDEPENDENTLY TO THE BATHROOM WET VENT IN BOTH | | | BATHROOMS PER FBC RES P3108.1. | | | B. PROVIDE A WATERSEAL TRAP FOR THE SHOWER, TUB AND | | | WASHER PER FBC RES P3201.6. | | | C. WASHER STANDPIPE SHALL NOT EXCEED 42' INLENGTH PER | | | FBC RES P2706.1.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | SINCERELY, | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | 561-805-6715 | | | [email protected] | | | |
|