| 2019-01-17 12:44:19 | 1ST REVIEW FBC-2017 MECHANICAL |
| | PERMIT #19010171 |
| | 1/17/19 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THE PLAN AND PERMIT APPLICATION ARE INDICATING AN AC |
| | CHANGE OUT, HOWEVER THE PROPERTY APPRAISOR'S REPORT |
| | INDICATES THE RESIDENCE DOES NOT HAVE A HEATING OR AIR |
| | CONDITIONING SYSTEM. THIS IS A NEW INSTALLATION OF AN |
| | AC SYSTEM. |
| | |
| | 2) PLEASE REVISE THE PLANS TO INDICATE A NEW AIR AC |
| | SYSTEM, AND PROVIDE A COMPLETE DUCT LAYOUT AND AC |
| | EQUIPMENT SCHEDULE ON THE PLAN.- SECTION 107.2.1 WPB. |
| | PLEASE INCLUDE DUCT SIZES AND CFM SUPPLY AT EACH |
| | DIFFUSER. |
| | |
| | 3) IDENTIFY ALL ROOMS ON THE PLAN AND SHOW REQUIRED |
| | RETURNS FROM BEDROOMS, AND THE LOCATION OF THE MAIN |
| | RETURN TO THE AIR HANDLER. INCLUDE TRANSFER GRILL |
| | DIMENSIONS AND RETURN CFMS- M1602.3 FBC R |
| | |
| | 4) PROVIDE AN AC EQUIPMENT SCHEDULE ON THE PLAN THAT |
| | INCLUDES THE MAKES AND MODELS OF THE CONDENSER AND AIR |
| | HANDLER, COOLING AND HEATING CAPACITIES, EFFICIENCY |
| | RATING, AND ELECTRICAL DATA- SECTION 107.2.1 WPB. |
| | |
| | 5) PROVIDE ENGINEERING FOR INSTALLATION OF THE AC |
| | CONDENSER- SECTIONS M1305.1.4.1 AND M1401.4 FBC R. |
| | |
| | 6) PROVIDE A CONDENSATE DISPOSAL PLAN- SECTIION M1411.3 |
| | FBC R. |
| | |
| | 7) SUBMIT AN ENERGY COMPLIANCE REPORT- SECTION R503.2 |
| | AND R401.2 FBC EC. |
| | |
| | 8) THE $3500.00 JOB VALUE ON THE APPLICATION IS LOW FOR |
| | THE PROPOSED PROJECT. SUBMIT A COPY OF THE CONTRACT, |
| | INVOICES ETC. TO VERIFY ACCURATE JOB VALUE- SECTION |
| | 109.3 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| | KEEP THEM WITH THE SUBMITTALS |
| | |