Plan Review Notes
Plan Review Notes For Permit 18120817
Permit Number 18120817
Review Stop B
Sequence Number 3
Notes
Date Text
2019-11-20 14:54:53NOTE:
 BUILDING REVIEW WILL BE APPROVED WITH PROVISO ONCE THE
 OWNER SIGNS AND DATE THE ENERGY CALCULATIONS AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION TO
 ISSUE THE PERMIT.
  
  
 ENERGY CALCULATIONS SUBMITTED:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE PRIOR TO RECEIVING THE PERMIT AS REQUIRED BY SEC.
 R103.1.1.2 FBC-ENERGY CONSERVATION.
  
  
  
  
 BUILDING REVIEW APPROVED WITH PROVISO (PROVIDE REQUIRED
 INFORMATION PRIOR TO INSPECTIONS TO AVOID
 CONFLICTS/DELAYS):
 1)ENGINEER TO REVISE WINDOWS DESIGN PRESSURES: DESIGN
 PRESSURES SHOWN FOR THE HORIZONTAL ROLLING WINDOWS
 SEEMS TO BE TOO LOW BASED ON THE BUILDING EXPOSURE.
 PROVIDE CALCULATIONS SHOWING WHY THEY ARE SO LOW. SEC.
 107.2.1.2 CITY AMENDMENTS. ALSO, CLARIFY WHY THE DESIGN
 PRESSURES FOR HORIZONTAL ROLLING WINDOW LOCATED IN
 BEDROOM #2 ARE THE SAME IF THIS WINDOW SEEMS TO BE
 LOCATED IN ZONE 5. (NOTE: ACCORDING TO FIGURE R301.2(7)
 THE MINIMUM DISTANCE FOR ZONE 5 IS 4'-0")
  
  
 2-PROVIDE PRODUCT APPROVAL (2 COPIES) REVIEWED BY
 ENGINEER OF RECORD FOR:
 A)GARAGE DOORS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER OF RECORD.
  
 B)HORIZONTAL SLIDING WINDOWS THAT WILL MEET THE REVISED
 DESIGN PRESSURES CALCULATED BY THE ENGINEER OF RECORD.
  
 C)SINGLE HUNG WINDOWS THAT WILL MEET THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER OF RECORD FOR ALL
 SIZES SHOWN ON PLANS.
  
 D)EXTERIOR SWING DOORS. PROVIDE COMPLETE PRODUCT
 APPROVAL. MISSING THE DOOR DRAWINGS.
  
 3- PROVIDE COMPLETE HURRICANE SHUTTERS INSTALLATION
 SCHEDULE (SEE CITY SAMPLE) FOR REVIEW PRIOR TO
 INSPECTION TO AVOID CONFLICTS/DELAYS.
  
 4-ENGINEER TO PROVIDE CALCULATIONS FOR THE FASTENING OF
 THE GARAGE STRUCTURAL BUCK. SPECIFICATIONS SHOWN ON
 STRUCTURAL BUCK DETAIL ON SHEET S.3 DON'T MATCH
 SPECIFICATIONS SHOWN ON THE GARAGE DOOR PRODUCT
 APPROVAL AND THE STRUCTURAL BUCK IS ATTACHED TO FILLED
 CONCRETE BLOCK CELL NOT TO CONCRETE. SEC. 107.2.1.2
 CITY AMENDMENTS.
  
  