| Plan Review Notes For Permit 18120787 |
| Permit Number |
18120787 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-12-21 14:50:16 | RESIDENTIAL (R2) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- FLAT ROOF: | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2 | | | COPIES) FOR PERIMETER AND CORNER AREAS AS REQUIRED BY | | | GENERAL LIMITATION #7 OF NOA 16-1206.02 SUBMITTED. SEC. | | | 1609.1.1 FBC. | | | | | | 2- CLAY TILE: | | | PROVIDE PRODUCT APPROVAL (2 COPIES) FOR ADHESIVE THAT | | | IS LISTED IN THE CLAY TILE NOA 15-0915.09 SUBMITTED AND | | | CLEARLY MARK PADDY SIZE. NOA 15-1201.04 SUBMITTED FOR | | | ADHESIVE RTA-1 IS NOT LISTED IN THE CLAY TILE NOA | | | SUBMITTED. | | | FAC 61G20-3.001. | | | | | | 3-CLEARLY IDENTIFY WHICH ROOF TILE UNDERLAYMENT FROM | | | NOA 17-0614.22 SUBMITTED IS GOING TO BE INSTALLED. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|