| Plan Review Notes For Permit 18120663 |
| Permit Number |
18120663 |
|
| Review Stop |
M |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-03-28 10:08:37 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18120663 | | | 3/2819 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE APPLICANT DID NOT UPLOAD THE CAPTIVE-AIRE | | | DRAWINGS WHEN THEY SWITCHED FROM PAPER TO DIGITAL. | | | PLEASE READ COMMENT #1 FROM THE 1ST REVIEW PRINTED | | | BELOW. | | | | | | 1) SUBMIT TWO COPIES OF SIGNED AND SEALED PLAN SHEETS | | | M-2-2-B, M2-3-B, MEPO-3, AND REMOVE ALL OTHER PLAN | | | SHEETS FROM THE SUBMITTAL EXCEPT FOR THE SIGNED AND | | | SEALED HOOD DRAWINGS FROM CAPTIVE-AIRE. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|