| 2018-12-06 18:58:25 | RESIDENTIAL (R3) SITE WALL BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | |
| | 1- SHEET 006 S-001A: |
| | A) MISSING DETAIL 4/S-001A KEYED ON PROPOSED PERIMETER |
| | SITE WALL PLAN ON SHEET 003 A-003. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | B) MISSING DETAIL 5/S-001A KEYED ON PROPOSED PERIMETER |
| | SITE WALL PLAN ON SHEET 003 A-003. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 3- PROPOSED PERIMETER SITE WALL PLAN ON SHEET 003 A-003 |
| | IS KEYING DETAIL 2/S001A AT THE SOUTH WALL. THIS DETAIL |
| | DOESN'T SEEM TO APPLY IN THIS AREA. REVISE/CLARIFY AS |
| | REQUIRED. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 4- THIS IS A DIGITAL SUBMITTAL. PROVIDE ALL STRUCTURAL |
| | ENGINEER'S DRAWINGS WITH DIGITAL SIGNATURE OR PROVIDE |
| | HARD COPIES WITH ORIGINAL SEAL AND SIGNATURE. CHAPTER |
| | 471 F.S. |
| | |
| | 5- THIS IS A DIGITAL SUBMITTAL. PROVIDE SOIL TEST |
| | REPORT WITH DIGITAL SIGNATURE OR PROVIDE HARD COPIES |
| | WITH ENGINEER'S ORIGINAL SEAL AND SIGNATURE. CHAPTER |
| | 471 F.S. |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |