| 2019-01-10 13:28:09 | CODES IN EFFECT: |
| | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 5TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 2ND REVIEW: DENIED |
| | PLUMBING COMMENTS |
| | PER FBC PL TABLE 403.1, A DRINKING FOUNTAIN AND SERVICE |
| | SINK IS REQUIRED BASED UPON FBC TABLE 1004.1.2 FOR |
| | GROUP B BUSINESS GROSS 100'; 1800 SQ FT/100=18 |
| | OCCUPANTS |
| | IT HAS BEEN DETERMINED BY THE BUILDING OFFICIAL THAT |
| | REGARDLESS OF THE NUMBER OF EMPLOYEES AND POSSIBLE |
| | CUSTOMERS THAT MIGHT BE OCCUPYING THE SPACE AT ANY |
| | GIVEN TIME, THE OCCUPANCY LOAD IS STILL 18 PERSONS. BY |
| | NOT REQUIRING THE DRINKING FOUNTAIN AND SERVICE SINK, |
| | THE NEXT TENANT WOULD BE DEEMED OUT OF COMPLIANCE |
| | PLACING AN UNFAIR BURDEN ON THAT TENANT. |
| | THE OCCUPANCY LOAD COULD BE LOWERED BY CONVERTING A |
| | PORTION OF THE SPACE TO STORAGE WHICH HAS AN OCCUPANT |
| | LOAD FACTOR OF 300 GROSS. YOU WOULD HAVE TO REDUCE THE |
| | GROUP B AREA TO 1300 SQ. FT. TO ALLOW AN OCCUPANT LOAD |
| | OF 13 + 2 FOR 500 SQ. FT. OF STORAGE TO EQUAL 15. THIS |
| | WOULD HAVE TO BE REFLECTED ON RESUBMITTED SIGNED AND |
| | SEALED PLANS IN PER WPB FBC 107.2.1. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |