Plan Review Notes
Plan Review Notes For Permit 18111060
Permit Number 18111060
Review Stop Z
Sequence Number 1
Notes
Date Text
2018-12-19 17:06:41FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) PLEASE PROVIDE VERIFICATION IN THE FORM OF A SURVEY
 TO VERIFY THAT THE PROPOSED FACILITIES ARE LOCATED
 WITHIN THE RIGHT-OF-WAY AND NOT ON PRIVATE PROPERTY.
 THE SUPPLIED PLAN IS SIGNED AND SEALED BY AN ENGINEER,
 NOT A SURVEYOR. THE BACK OF A SIDEWALK IS TYPICALLY THE
 BOUNDARY BETWEEN THE RIGHT-OF-WAY AND THE PRIVATE
 PROPERTY, SO THE POLE AND PROPOSED EQUIPMENT THAT ARE
 SHOWN NOT WITHIN THE SIDEWALK MAY BE ON PRIVATE
 PROPERTY.
  
 2) PROVIDE CONSENT FROM FPL, THE OWNER OF THE UTILITY
 POLE, THAT PERMITS THE PLACEMENT OF THE ANTENNAS AND
 RELATED EQUIPMENT ON IT.
  
 3) ANY PORTION OF THE ANTENNA OR EQUIPMENT THAT IS ON
 PRIVATE PROPERTY IS NOT LOCATED WITHIN THE RIGHT-OF-WAY
 AND REQUIRES THE APPROVAL OF A CITY PRIVATE PROPERTY
 WIRELESS COMMUNICATION PERMIT IN ACCORDANCE WITH
 ARTICLE X OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS. PLEASE CONTACT ME FOR A COPY OF THE
 WIRELESS COMMUNICATION PERMIT APPLICATION.
  
 4) THE CITY REQUIRES THAT THE EQUIPMENT CABINETS
 (UTILITY METER, DISCONNECT AND NEMA BOX) BE SCREENED,
 IN THIS CASE WITH A DECORATIVE WRAP. PLEASE SHOW HOW
 THIS WILL OCCUR. NOTE: WHILE THE PLANS CALL THE
 EQUIPMENT CABINETS' HEIGHT AT A MAXIMUM OF SIX (6)
 FEET, PLEASE CONSIDER HAVING THEM MOUNTED ON A SHORTER
 POLE TO MINIMIZE THE VISUAL IMPACT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]
  
2018-11-30 08:19:48ROUTED TO AJV
 MC