| Date |
Text |
| 2018-12-26 09:11:06 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | 1&2 FAMILY PLANS EXAMINER, SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. PROVIDE ELEVATION CERTIFICATE. |
| | |
| | 1612.4 DESIGN AND CONSTRUCTION. |
| | THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES |
| | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH |
| | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF |
| | ASCE 7 AND WITH ASCE 24. |
| | |
| | FBC 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY) & |
| | R322.2.1 ELEVATION REQUIREMENTS. BUILDINGS AND |
| | STRUCTURES IN FLOOD HAZARD AREAS NOT DESIGNATED AS |
| | COASTAL A ZONES SHALL HAVE THE LOWEST FLOORS ELEVATED |
| | TO OR ABOVE THE DESIGN FLOOD ELEVATION. PROVIDE FLOOD |
| | DESIGN INFORMATION ON THE PROPOSED SURVEY AND PROVIDE |
| | FLOOD ELEVATION CERTIFICATE. |
| | |
| | G1001.4 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. |
| | FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION |
| | SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO |
| | THE FOLLOWING: |
| | |
| | 1. IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY |
| | WAVE ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS |
| | TO ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF |
| | FLOODWATERS. |
| | |
| | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS |
| | AE WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY |
| | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN |
| | ADDITIONAL 24 INCHES OF FREEBOARD REQUIRING THE DESIGN |
| | FLOOD ELEVATION (DFE) TO BE 8. 0 FEET. PLEASE NOTE THIS |
| | INFORMATION ON YOUR PLANS. |
| | |
| | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS |
| | REQUIRED AT TIME OF PERMIT APPLICATION. |
| | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS |
| | SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NAVD. |
| | |
| | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED |
| | FLOOR ELEVATION IS RECOMMENDED. |
| | |
| | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| | |
| | |
| | |
| | |