Plan Review Notes
Plan Review Notes For Permit 18110717
Permit Number 18110717
Review Stop B
Sequence Number 1
Notes
Date Text
2018-12-04 16:43:081ST REVIEW: FBC 2017 6TH EDITION
 1ST REVIEW FBC 2017 EXISTING BUILDING
  
 BUILDING - FAILED
  
 PLEASE PROVIDE CODE INFORMATION ON PLAN. IT APPEARS THE
 CODE INFORMATION SHOULD BE AS FOLLOWS:
  
 FBC 2017 6TH EDITION
 FBC 2017 EXISTING BUILDING
 ALTERATION LEVEL II
 TYPE IIB CONSTRUCTION NON-COMBUSTIBLE
  
 FBC 107 MINIMUM PLAN REVIEW CRITERIA - PROVIDE DETAILS
 OF THE NEW WALL FRAMING AND FINISHES, WITH A TYPICAL
 WALL SECTION.
  
 IS FLOORING TO BE INSTALLED AT THE BATH TUB REMOVAL
 AREA? PLEASE CLARIFY. THE PLAN IS NOT CLEAR IF THERE IS
 EXISTING FLOORING TO REMAIN. IF SO, PROVIDE FLOORING
 INSULATION AND FLOORING TYPE INFORMATION. FOR SOUND
 INSULATION PROVIDE TEST REPORTS DEMONSTRATING
 COMPLIANCE WITH THE FOLLOWING SECTIONS:
  
 FBC 603.1 FLAME SPREAD; INSULATION BETWEEN A FINISHED
 FLOOR AND SOLID DECKING W/O AN INTERVENING SPACE
 W/FLAME SPREAD INDEX OF 200 OR LESS.
  
 FBC 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  