| Plan Review Notes For Permit 18110604 |
| Permit Number |
18110604 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-01-24 08:55:35 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED WITH PROVISO: | | | | | | 1. PROVIDE A COMPLETED FORM BOARD SURVEY (INCLUDING | | | ELEVATIONS & WATER RUN-OFF/DRAINAGE INDICATORS) AND | | | ELEVATION CERTIFICATE AT TIME OF SLAB INSPECTION. | | | | | | 2. HAVE THE APPROVED ROOFING PERMIT ON-SITE PRIOR TO | | | BEGINNING ROOF WORK. | | | | | | NOTES: | | | | | | AT TIME OF INSPECTION, PLEASE PROVIDE THE FOLLOWING | | | INFORMATION FOR THE INSPECTOR. | | | | | | FBC R 314 AND 315 LISTED AND LABELED CARBON MONOXIDE | | | AND SMOKE DETECTORS ARE REQUIRED. | | | | | | AWS D1.1 CLAUSE 3.1 AND 4.15 AT TIME OF INSPECTION, FOR | | | THE STEEL COLUMN, PROVIDE A WELD PROCEDURE | | | SPECIFICATION; (SPECIFIES THE ESSENTIAL VARIABLES | | | INCLUDING: BASE MATERIALS, THE JOINTS, THE WELDING | | | PROCESS, AND THE FILLER METALS TO BE USED). | | | ALSO, PROVIDE THE WELDERS PERFORMANCE QUALIFICATION | | | RECORD; (SHOWS THE WELDER IS QUALIFIED & CERTIFIED FOR | | | THE DESCRIBED TYPE OF WELDING REQUIRED ON THIS | | | PROJECT). | | | | | | THE TRUSS ENGINEERING PACKAGE. | | | | | | |
|