Plan Review Notes
Plan Review Notes For Permit 18110199
Permit Number 18110199
Review Stop B
Sequence Number 1
Notes
Date Text
2018-12-08 15:19:51****CORRECTIONS****
  
 SAMANTHA HILL / JOSEAN DUPREY
 BUILDING PLANS EXAMINER
 [email protected], [email protected]
 561-805-6719
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. A 1.1 HAS IRRELEVANT NOTES (OR NON COMPLIANT); FOR
 INSTANCE, ROUGH CARPENTRY SPECIFIED BUT THIS IS A NON
 COMBUSTIBLE BUILDING. REVISE TO REMOVE NOTES NOT
 APPLICABLE OR CLARIFY, FBC 107.
  
 2. A1.2 HAS INCORRECT NOTES; BROWARD COUNTY IS
 REFERENCED, ANSI/ASCE 7-10; CHECK ALL AND REVISE.
  
 3. A SIGNIFICANT PORTION OF THE FLOOR PLAN ON SHEET
 LS1.0 HAS BEEN HATCHED OFF AS "NO OCCUPANTS". GROSS
 SQUARE FOOT AREA IS TO BE USED TO CALCULATE OCCUPANCY,
 REVISE, SEE FBC B TABLE 1004.1.2.
  
 4. IT IS NOT CLEAR IF AN ACCESSIBLE ROUTE HAS BEEN
 PROVIDED TO THE MANICURE AREA, FBC A 202.4. THERE IS A
 SHELF BEHIND THE MANICURE AREA WHICH APPEARS TO
 OBSTRUCT THE ACCESSIBLE ROUTE. IF THIS IS THE "WORK
 AREA" SIDE, THE ABILITY TO ENTER AND EXIT IS TO BE
 PROVIDED FBC A 203.9. REVISE PLAN TO CLEARLY
 DEMONSTRATE COMPLIANCE.
  
 5. IT APPEARS THAT THE RECEPTION DESK WILL BE USED TO
 CHECK OUT; SEE FBC A 904.4.3, 904.4 AND REVISE PLAN TO
 SHOW COMPLIANCE.
  
 6. A MICROWAVE IS SHOWN BUT HEIGHT IS NOT CLEAR. REACH
 RANGE DETAILS WERE PROVIDED BUT IT IS NOT CLEAR IF THE
 PROPOSED LOCATION COMPLIES, AND IF NOT, IF THERE IS
 ANOTHER OPEN SHELF WITH OUTLET ACCESS WHICH DOES MEET
 THE REQUIREMENT IN THE EVENT ACCOMODATION WAS NEEDED,
 FBC A 804.6.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved