| Date |
Text |
| 2018-12-08 15:19:51 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL / JOSEAN DUPREY |
| | BUILDING PLANS EXAMINER |
| | [email protected], [email protected] |
| | 561-805-6719 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. A 1.1 HAS IRRELEVANT NOTES (OR NON COMPLIANT); FOR |
| | INSTANCE, ROUGH CARPENTRY SPECIFIED BUT THIS IS A NON |
| | COMBUSTIBLE BUILDING. REVISE TO REMOVE NOTES NOT |
| | APPLICABLE OR CLARIFY, FBC 107. |
| | |
| | 2. A1.2 HAS INCORRECT NOTES; BROWARD COUNTY IS |
| | REFERENCED, ANSI/ASCE 7-10; CHECK ALL AND REVISE. |
| | |
| | 3. A SIGNIFICANT PORTION OF THE FLOOR PLAN ON SHEET |
| | LS1.0 HAS BEEN HATCHED OFF AS "NO OCCUPANTS". GROSS |
| | SQUARE FOOT AREA IS TO BE USED TO CALCULATE OCCUPANCY, |
| | REVISE, SEE FBC B TABLE 1004.1.2. |
| | |
| | 4. IT IS NOT CLEAR IF AN ACCESSIBLE ROUTE HAS BEEN |
| | PROVIDED TO THE MANICURE AREA, FBC A 202.4. THERE IS A |
| | SHELF BEHIND THE MANICURE AREA WHICH APPEARS TO |
| | OBSTRUCT THE ACCESSIBLE ROUTE. IF THIS IS THE "WORK |
| | AREA" SIDE, THE ABILITY TO ENTER AND EXIT IS TO BE |
| | PROVIDED FBC A 203.9. REVISE PLAN TO CLEARLY |
| | DEMONSTRATE COMPLIANCE. |
| | |
| | 5. IT APPEARS THAT THE RECEPTION DESK WILL BE USED TO |
| | CHECK OUT; SEE FBC A 904.4.3, 904.4 AND REVISE PLAN TO |
| | SHOW COMPLIANCE. |
| | |
| | 6. A MICROWAVE IS SHOWN BUT HEIGHT IS NOT CLEAR. REACH |
| | RANGE DETAILS WERE PROVIDED BUT IT IS NOT CLEAR IF THE |
| | PROPOSED LOCATION COMPLIES, AND IF NOT, IF THERE IS |
| | ANOTHER OPEN SHELF WITH OUTLET ACCESS WHICH DOES MEET |
| | THE REQUIREMENT IN THE EVENT ACCOMODATION WAS NEEDED, |
| | FBC A 804.6. |
| | |
| | |